Evaluasi, Perancangan Perbaikan, dan Metode Perbaikan Dinding Penahan Tanah pada Komplek Perkantoran UPT Pembibitan Dispangtan Ujung Berung Bandung

Evaluation, Repair Design, And Repair Method of Retaining Wall at Komplek Perkantoran UPT Pembibitan Dispangtan Ujung Berung Bandung

Skripsi, 016 / 2021 / TPPG
Undergraduate Theses from JBPTPPOLBAN / 2022-09-23 16:16:44
Oleh : Nur Afifah Fernawati - 171144022 & Oscar Reinaldi Ramdhani - 171144023 (oscar.reinaldi.tppg17@polban.ac.id)
Dibuat : 2022-09-23, dengan 4 file

Keyword : Dinding Penahan Tanah, Dinding Penahan Tanah Kantilever, Stabilitas Lereng, GeoStudio
Subjek : Retaining Wall, Cantilever Retaining Wall, Slope Stability, GeoStudio

Komplek Perkantoran UPT Pembibitan TPHP Dispangtan yang berlokasi di Kelurahan Cisurupan, Kecamatan Cibiru, Ujung Berung, Kota Bandung adalah komplek perkantoran dinas yang bertujuan untuk dijadikan sarana edukasi lingkungan hidup bagi masyarakat Kota Bandung dan sekitarnya. Komplek perkantoran ini dibangun di atas lereng dengan menggunakan tanah timbunan dan ditahan oleh dinding penahan tanah jenis batu kali. Pada tahun 2018 lalu terjadi longsor pada dinding penahan tanah eksisting. Dikarenakan kurang kuatnya dinding penahan tanah eksisting dalam menahan guling dan gesernya, maka dilakukan evaluasi stabilitas dinding penahan tanah eksisting untuk dapat merancang perbaikan yang dibutuhkan dan menentukan metode pelaksanaan yang sesuai. Perbaikan dinding penahan tanah eksisting dilakukan dengan menambahkan struktur dinding kantilever. Dalam perancangan ini dilakukan perhitungan pembebanan gedung laboraotium, analisis stabilitas lereng menggunakan Software GeoStudio Slope W/, evaluasi stabilitas dinding penahan tanah eksisting terhadap guling dan geser dengan menghitung tekanan tanah lateral aktif dan pasif, menentukan alternatif perbaikan menggunakan metode perbandingan, merancang dimensi dan penulangan dari dinding penahan tanah yang diambil, membuat Detailed Engineering Design perbaikan dan menentukan metode pelaksanaan yang sesuai dengan situasi dan kondisi di lapangan. Berdasarkan hasil perancangan yang telah dilakukan, didapatkan perbaikan menggunakan dinding penahan tanah kantilever setinggi 7,1 m dengan tebal badan 0,5 m serta dimensi kaki diding selebar 2,5 m dengan tebal kaki 0,7 m, dengan tuulangan utama dinding adalah D16-250 dan tulangan susut D10-100. Dan untuk tulangan utama pada kaki dinding adalah D16-100 serta tulangan susut D10-100.

Deskripsi Alternatif :

Office Complex UPT Pembibitan TPHP Dispangtan located in the Village Cisurupan, District Cibiru, Ujung Berung, Bandung City is the official office complex that aims to serve as an environmental education facilities for Bandung people and its surroundings. This office complex is built on a slope using backfill soil and is supported by a gravity retaining wall. In 2018, a landslide occurred on the existing retaining wall. Due to the lack of strength of the existing retaining wall in resisting overturning and shearing, it is necessary to evaluate the stability of the existing retaining wall to be able to design the necessary repairs and determine the appropriate implementation method. Repair of the existing retaining wall is designed using a cantilever retaining wall. In this design process is calculation loading of laboratory building, slope stability analysis using GeoStudio Slope W/ Software, evaluation of the stability of the existing retaining wall against overturning and shearing by calculating active and passive lateral earth pressures, determining repairing alternative design using the comparison method, designing dimension and reinforcement of retaining wall design taken, designing Detailed Engineering Design repair, and determining the implementation method according to the situation and condition in the construction field. Based on the results of the design, it is found that existing retaining wall repair using cantilever retaining walls that have 7.1 m high of the body with it is thickness 0.5 m and the wide of foot is 2.5 m with it is thickness 0.7 m, for the main bar of the wall is D16-250 and the stirrup bar is D10-100. Also for the main bar of the foot is D16-100 and the stirrup bar is D10-100.

Beri Komentar ?#(4) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Muchtar, S.ST., M.T.

    Pembimbing 2: Dr. Syahril, BSCE., M.T., Editor: Erlin Arvelina

Download...