Path: Top > Tugas Akhir - D3 > Jurusan Teknik Refrigerasi dan Tata Udara > Program Studi Teknik Refrigerasi dan Tata Udara > 2016

Analisis Performansi Sistem Refrigerasi Termoelektrik pada Tempat Penyimpanan Sementara Air Susu Ibu

Analysis of the performance of thermoelektric refrigeration system at the temporary storage of breast milk

Tugas Akhir, 020 / 2016 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2017-09-04 10:35:35
Oleh : Nurahmah Yanti - 131611020 (nurahmahyanti03@gmail.com)
Dibuat : 2017-08-30, dengan 4 file

Keyword : Thermoelectrically Cooling / TEC, ASI, COP, Efficiency.
Subjek : Thermoelektrik Cooling/TEC, ASI, COP, Efisiensi.

Di negara berkembang, kasus bayi dengan Low Birth Weight Infants erat kaitannya dengan tingkat kemiskinan sehingga masyarakat kurang mampu untuk membeli inkubator yang sudah dilengkapi dengan tempat penyimpanan ASI. Tempat penyimpanan sementara air susu ibu dengan media pendinginan termoelektrik (Thermoelektrik Cooling/TEC) yang digunakan dalam pengerjaan Tugas Akhir ini untuk mengetahui temperatur pendinginan yang dapat dicapai untuk jumlah modul TEC sebanyak 4 buah dengan pengoperasian fan. Pada penelitian ini digunakan produk untuk didinginkan yaitu Susu Formula sebagai pengganti ASI sebanyak 2 botol ,dengan ukuran tiap botol 120 ml susu. Penggunaan 4 modul termoelektrik dengan penggunaan fan selama 2 jam dapat menghasilkan temperatur kabin sebesar 18 ºC, COPactual 1,40 COPcarnot 3,748 dan efisiensi 37,3%. Kata kunci : Thermoelektrik Cooling/TEC, ASI, COP, Efisiensi.

Deskripsi Alternatif :

In developing countries, infants with Low Birth Weight Infants closely related to the level of poverty so that people are less able to buy an incubator that has been fitted with a breast milk storage. Temporary storage of breast milk with thermoelectric cooling media (thermoelectrically Cooling / TEC), which is used in the execution of this Final to determine the temperature of cooling that can be achieved for a number of modules TEC 4 units with fan operation. In this study used the product to be cooled is Formula as much as 2 bottles of breastmilk substitutes, with the size of each bottle of 120 ml of milk. The use of four thermoelectric modules with the use of a fan for 2 hours can generate cabin temperatures by 18 ° C, 1.40 COPactual COPcarnot 3.748 and efficiency of 37.3%. Keywords: thermoelectrically Cooling / TEC, ASI, COP, Efficiency.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing : Aries Prih Haryono,ST., MT ; Ir. Eddy Erham, MT, Editor: Muhammad Abdillah Islamy, S.Pd

Download...