Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknologi Pembangkit Tenaga Listrik > 2018
Rancangan Multi Stage Flash Tipe Once Through Untuk Meningkatkan Kinerja Multi Stage Flash Pada Pembangkit Listrik Tenaga Uap 3X600MW
The Design of Multi Stage Flash Once Through for Increase the Performance Multi Stage Flash in 3X600MW Steam Powerplant
Skripsi, 020 / 2018 / TPTLUndergraduate Theses from JBPTPPOLBAN / 2019-01-10 09:19:25
Oleh : Nurlatipah - 141724023 (nurlatipah43@gmail.com)
Dibuat : 2019-01-10, dengan 4 file
Keyword : Desalinasi, PLTU, MSF-OT, freshwater, performa, Gain Output Ratio (GOR), kondensasi
Subjek : desalination, steam powerplant, MSF-OT, freshwater, performance, Gain Output Ratio (GOR), condensation
Desalinasi air laut adalah sesuatu yang penting dalam industri proses, salah satunya dalam teknologi pengolahan dan pemurnian air di Pembangkit Listrik Tenaga Uap (PLTU). Multi Stage Flash (MSF) Desalination merupakan salah satu teknologi yang banyak digunakan dalam pengolahan air yang memiliki keterlibatan penting dalam menghasilkan freshwater. MSF yang digunakan pada pembangkit terpasang untuk memenuhi kebutuhan air pembangkit 3X600MW menggunakan MSF tipe brine recirculation (MSF-BC). MSF-BC mengkonsumsi uap sebesar 4,522 kg/s untuk menghasilkan air destilat 36,914 kg/s. Hal ini menjadi dasar untuk melakukan rancangan baru menggunakan Multi Stage Flash Tipe Once Through. Pemodelan yang digunakan untuk perancangan menggunakan pemodelan matematika yang dikembangkan oleh El-Dessouky dan Ettouney. Proses desalinasi hasil rancangan membutuhkan sumber uap sebesar 4,15 kg/s untuk menghasilkan 36,914 kg/s air destilat. Kriteria rancangan MSF yakni dapat memproduksi 36,914 kg/s freshwater pada tekanan tiap stage kurang dari 1 atm. Rancangan dilakukan pada 17 stage, dengan kebutuhan air pembangkit dan data pendukung dari pembangkit terpasang menjadi referensi dalam proses perancangan baik pada tahap perhitungan neraca massa dan energi, analisa performa alat melalui besarnya Gain Output Ratio (GOR) yang dihasilkan, dan pada tahap simulasi serta rancangan alat. Kata kunci: Desalinasi, PLTU, MSF-OT, freshwater, performa, Gain Output Ratio (GOR), kondensasi.
Deskripsi Alternatif :Abstrak English: ABSTRACT is something important in industrial process, including water treatment and purification technology in steam powerplant. Multi Stage Flash (MSF) desalination is one of technology which many used in water treatment that has important involvement in producing fresh water. The MSF used in installed steam powerplant 3X600MW is MSF brine Recirculation (MSF-BC). MSF-BC consumses 4,522 kg/s of steam to produces destillates. This is basic for redesign MSF with Multi Stage Flash Once Through. Modeling mathematical for design used modelling developed by El-Dessouky and Ettouney. The design desalination prosess uses 4,15 kg/s steam to produce 36,914 kg/s distillate. Design criteria for MSF is that it can produce 36,914 kg/s fresh water at pressure of each stage which is less than 1 atm. The design is done in 17 stages, with powerplant water needs and supporting data from installed powerplant that become reference in design process which is in mass and energy balance calculation step, MSF performance analysis through the results of Gain Output Ratio (GOR), and simulation step also MSF design. Keywords: desalination, steam powerplant, MSF-OT, freshwater, performance, Gain Output Ratio (GOR), condensation.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Dra. Tina Mulya Gantina, M.T.
Pembimbing 2: Sugianto, S.T., M.Eng., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN SKRIPSI - 141724023.pdf
(346521 bytes)
File : BAB 1 - 141724023.pdf
(212358 bytes)
File : BAB 2 - 141724023.pdf
(658769 bytes)
File : BAB 5 - 141724023.pdf
(260783 bytes)