ANALISIS PERFORMANSI FREEZER DENGAN METODA PUMP DOWN YANG MENGGUNAKAN R-290 UNTUK PENYIMPANAN IKAN

Performance Analysis Freezer With Pump Down Method Using R-290 For Fish Storage

Tugas Akhir, 066 / 2012 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2014-07-15 10:04:01
Oleh : Oin Figaluh - 091611023 (oin.race09@gmail.com)
Dibuat : 2014-07-15, dengan 4 file

Keyword : Freezer, pump down, hidrocarbon, liquid receiver, solenoid valve
Subjek : Frezeer, pump down, hydrocarbon,liquid receiver, solenoid valve

Pemakaian dan penggunaan sistem refrigerasi untuk keperluan komersil dan industry kini semakin banyak digunakan, terutama sebagai sarana untuk tempat penyimpanan yang membutuhkan temperatur yang rendah dan konstan. Sebagai contoh adalah ikan merupakan salah satu produk yang mudah rusak dan busuk apabila berada di atas temperatur 20°C. Oleh sebab itu diperlukan mesin pendingin untuk mengawetkan ikan tersebut agar tidak cepat rusak. Oleh karena itu tujuan yang ingin dicapai dalam tugas akhir dengan judul "Analisis Performansi Freezer Dengan Metoda Pump Down Yang Menggunakan R-290 Untuk Penyimpanan Ikan" yaitu didapatkannya suatu perbandingan kinerja antara sistem R-290 dengan R-22 pada Freezer. Untuk Metoda pengambilan data dilakukan pada titik pengukuran yang telah ditentukan setaiap 10 menit sekali. Untuk dapat menghasilkan analisis yang akurat, diantaranya adalah mencatat data tekanan, temperatur, serta arus listrik sejak awal hingga kondisi mesin steady yang mencapai temperature evaporator -200C. Setelah dilakukan pengujian, pengambilan data, dan analisa didapat COP rata-rata adalah 2.42 dengan arus rata-rata 2.23 ampere. Kata kunci : Freezer, pump down, hidrocarbon, liquid receiver, solenoid valve

Deskripsi Alternatif :

Consumption and use of refrigeration systems for commercial and industrial purposes is now more widely used, particularly as a means of storage that require constant low temperatures. An example is the fish is one product that is easily damaged and rotten when the temperature is above20°C.Therefore necessary refrigeration to preserve the fish that is not easily damaged. Objectives to be achieved in the final project titled "Performance Analysis Freezer With Pump Down Method Using R-290 For Fish Storage" is the obtainment of a performance comparison between systems using a product with no product in the Freezer. For methods of data collection conductedat pre determined measurement points set a 10 minutes.To be able to produce accurate analysis, such as a data record pressure, temperature, and the electric current from the beginning until steady state is reached engine evaporator temperature -20C. After the test, the data average of COP is 2.42 with average of current of current is 2.23 ampere. Keywords : Frezeer, pump down, hydrocarbon,liquid receiver, solenoid valve

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Triaji Pangripto Pramudantoro, ST., M.Eng.

    Pembimbing 2: Tandi Sutandi, SST.
    , Editor: Erlin Arvelina

Download...