Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknik Konservasi Energi > 2018
Rancangan Motor Listrik Penggerak Mesin Tablet Press Dengan Kapasitas 1250 TPM
Electric Motor Design As Tablet Press Machine Mover With Capacity 1250 TPM
Skripsi, 016 / 2018 / TKEUndergraduate Theses from JBPTPPOLBAN / 2019-01-09 13:49:11
Oleh : Raditya Galih Barliansyah - 141734025 (risolihyummy@gmail.com)
Dibuat : 2019-01-09, dengan 4 file
Keyword : Tablet Press, Motor Listrik, Efisiensi
Subjek : Tablet Press, Electric Motor, Efficiency
Perkembangan teknologi dan permintaan konsumsi energi harus dikendalikan dari sumber (source) dan sisi konsumen (demand). Berdasarkan Peraturan Pemerintah Nomor 70 tahun 2009 tentang konservasi energi, pada produksi obat solid di sektor farmasi terdapat banyak mesin yang memerlukan konservasi energi, salah satunya adalah Tablet Press Machine yang kecepatan produksinya ditentukan oleh motor listrik. Motor listrik menggunakan sekitar 70% dari energi listrik yang dikonsumsi oleh industri. Saat ini industri mencari teknologi motor listrik dengan energi yang efisien, maka dilakukan rancang dan uji pada motor listrik penggerak Mesin Tablet Press tersebut. Rancangan dimulai dari menentukan spesifikasi berdasarkan beban operasi lalu menentukan kelas efisiensi dan spesifikasi berupa nilai nominal, jumlah lilitan dan dimensi. Permodelan rancangan digambar menggunakan perangkat lunak Solidwork. Selain spesifikasi motor listrik, nilai pengenal proteksi dan sirkit penghantar/kabel harus diperhitungkan, dan wiring digambar menggunakan perangkat lunak autoCAD. Didapatkan spesifikasi dan jenis motor listrik yang optimal untuk penggerak mesin Tablet Press kapasitas 1250 TPM yaitu Motor Asinkron Rotor Lilit kelas B, 2.2 kW, dengan kelas efisiensi premium efficiency class yang nilai nominalnya sebesar 86.7%. Hasil perancangan harus diuji kinerjanya dan dilakukan analisa terhadap nilai kinerja. Dari hasil analisis dan perhitungan kinerja, didapatkan nilai efisiensi motor listrik sebesar 86.37% saat faktor pembebanan 78.5% dimana nilai daya input/beban operasi sebesar 1727.26 W. Perhitungan efisiensi menggunakan pendekatan rugi-rugi dan simulasi menggunakan software ETAP. Dan dari hasil analisis dapat disimpulkan nilai faktor pembebanan sangat mempengaruhi nilai efisiensi motor, nilai efisiensi akan maksimal jika motor listrik dijalankan minimal 80% dari kapasitas nominalnya. Kata Kunci: Tablet Press, Motor Listrik, Efisiensi.
Deskripsi Alternatif :Technological development and demand for energy consumption must be controlled from sources and consumers. Based on Government Regulation No. 70 of 2009 concerning energy conservation, in the production of solid medicines in the pharmaceutical sector there are many machines that require energy conservation, one of which is the Tablet Press Machine whose production speed is determined by an electric motor. Electric motors use about 70% of the electricity consumed by industry. At present the industry is looking for electric motor technology with efficient energy, so it is designed and tested on the electric motor driving the Tablet Press Machine. The design starts from determining specifications based on the operating load and then determining the efficiency class and specifications in the form of nominal value, number of turns and dimensions. Design modeling is drawn using Solidwork software. In addition to the specifications of the electric motor, the protection rating and conductor / cable circuit must be taken into account, and wiring is drawn using autoCAD software. Obtained the specifications and types of electric motors that are optimal for a 1250 TPM Tablet Press engine drive, namely Class B Rotor Rotor Asynchronous Motor, 2.2 kW, with efficiency efficiency class premium class with a nominal value of 86.7%. The results of the design must be tested for performance and analysis of the performance value. From the results of the analysis and calculation of performance, obtained the value of the electric motor efficiency of 86.37% when the loading factor is 78.5% where the value of the input power / operating load is 1727.26 W. The efficiency calculation uses the loss and simulation approach using ETAP software. And from the results of the analysis it can be concluded that the value of the loading factor greatly affects the value of motor efficiency, the efficiency value will be maximum if the electric motor is run at least 80% of its nominal capacity. Keywords: Tablet Press, Electric Motor, Efficiency.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Ir. Sapto Prajogo, M.Si.
Pembimbing 2: Ahmad Deni Mulyadi, S.T., M.T., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN SKRIPSI - 141734025.pdf
(1149906 bytes)
File : BAB 1 - 141734025.pdf
(315776 bytes)
File : BAB 2 - 141734025.pdf
(1692422 bytes)
File : BAB 5 - 141734025.pdf
(337803 bytes)