Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknik Konservasi Energi > 2019
Perancangan Cyclone Preheater Kapasitas 1950 Ton Pada Proses Produksi Semen di PT. Holcim Indonesia
Design of Cyclone Preheater Capacity 1950 Ton in Cement Production Process at PT. Holcim Indonesia
Skripsi, 023 / 2019 / TKEUndergraduate Theses from JBPTPPOLBAN / 2019-12-12 12:20:03
Oleh : Rasmohan Agni Klisme - 151734023 (rasmohanagni80@gmail.com)
Dibuat : 2019-12-12, dengan 4 file
Keyword : cyclone, geometri high efficiency stairmand, metode muschelknautzs
Subjek : cyclone, high efficiency stairmand geometry, Muschelknautz's method
Semen merupakan bahan baku utama yang mendukung proses pembangunan infrastruktur pada suatu negara khususnya di Indonesia. Proses produksi semen melibatkan banyak peralatan baik peralatan dalam proses utama maupun peralatan pendukung lainnya. Salah satu peralatan pada produksi semen yaitu cyclone preheater dengan jenis suspension preheater. Proses pemanasan dan pemisahan pada cyclone harus tetap dijaga agar proses dapat berlangsung dengan baik. Faktor desain cyclone yang tergolong sudah cukup lama sangat mempengaruhi efisiensi kinerja cyclone . Efisiensi cyclone pada tahun 1995 saat nama PT. Holcim masih PT. Semen Nusantara efiseinsi cyclone preheater 0,9 atau setara 90% dan tahun 2018 mengalami penurunan hingga 3% menjadi 0,87 atau setara 87% dengan input material hingga 90 mikron. Metode yang digunakan dalam perancangan cyclone dalam rangka pengoptimalan desain cyclone adalah metode kuantitatif dengan meggunakan rasio geomertry high efficiency Stairmand terdapat perubahan dimensi yang siginifikan yaitu ada pada tinggi cyclone sebelumnya yaitu 13 meter menjadi 18 meter, dan perubahan yang signifikan ada pada sisi lebar masuk feed cyclone yang sebelumnya 1,2 meter menjadi 0,9 meter. Data yang akan digunakan pada penelitian ini adalah data primer dan sekunder yang bersumber dari industri semen terkait, jurnal penelitian, text book, dan manual book. Pengolahan data berdasarkan metode perhitungan Muschelknautz's dan hasil perancangan akan disimulasikan menggukan perangkat lunak solid work. Berdasarkan analisa data yang dilakukan nilai efisiensi cyclone preheater mengalami peningkatan jika dibandingkan dengan nilai cyclone eksisting 0,87 menjadi 0,92. Parameter yang mengalami perubahan ialah penurunan parameter pressure drop eksisting dari 216,14 Pa menjadi 147,47 Pa setalah dilakukan perancangan. Dimensi perancangan cyclone preheater ini lebih panjang dan lebih kecil pada bagian sisi masuk feednya dibandingkan dengan dimensi eksisting sehingga bisa meningkatkan efisiensi pada cyclone. Kata kunci: cyclone, geometri high efficiency stairmand, metode muschelknautz's.
Deskripsi Alternatif :Cement is the main raw material that supports the process of infrastructure development in a country especially in Indonesia. The process of cement production involves a lot of equipment both in the main process and other supporting equipment. One of the equipments on the cement production is Cyclone preheater with the type of suspension preheater. The process of heating and separation of the cyclone must be kept so that the process can take place properly. The cyclone design factor, which is relatively long, affects the efficiency of cyclone performance. Cyclone efficiency in 1995 when the name of PT. HOLCIM is still PT. Semen Nusantara efiseinsi Cyclone preheater 0.9 or equivalent 90% and year 2018 decreased to 3% to 0.87 or equivalent 87% with material input up to 90 micron. Method used in cyclone design in order to optimize cyclone designs is a quantitative method, using a high efficiency geometry ratio Stairmand There is a significant dimensional change that is present at the high cyclone The previous one was 13 metres to 18 meters, and a significant change was on the entrance width of the cyclone feed that had previously 1.2 meters to 0.9 meters. The data to be used in this research is primary and secondary data sourced from the cement industry related, research journals, text books, and manual books. Data processing based on Muschelknautz's calculation method and design results will be simulated using solid work software. Based on the analysis of data done by the value of cyclone preheater efficiency increased compared with the existing Cyclone value 0.87 to 0.92. The changing parameter is the decrease in the existing pressure drop parameter from 216.14 Pa to 147.47 Pa after design. The design dimension of this cyclone Preheater is longer and smaller on the side of the feed in comparison with existing dimensions so that it can increase the efficiency of the cyclone. Keywords: cyclone, high efficiency stairmand geometry, Muschelknautz's method.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Bambang Puguh Manunggal, S.T., M.Eng.
Pembimbing 2: Dr. Ir. Sri Wuryanti, M.Si., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN SKRIPSI - 151734023.pdf
(1122638 bytes)
File : BAB 1 - 151734023.pdf
(239527 bytes)
File : BAB 2 - 151734023.pdf
(1057356 bytes)
File : BAB 5 - 151734023.pdf
(7618 bytes)