Rancang Bangun Instalasi Lightning Arrester 20 kV Pada Jaringan Distribusi Primer Di Politeknik Negeri Bandung
Design Of Installation Of Lightning Arresters 20 kV Primary Distribution In Polytechnic State Of Bandung
Tugas Akhir, 046 / 2015 / TLIUndergraduate Theses from JBPTPPOLBAN / 2018-07-06 10:55:58
Oleh : Razie Azfar Tanjung - 121321025 (razieazfartanjung@yahoo.co.id)
Dibuat : 2018-07-06, dengan 4 file
Keyword : sistem proteksi, tegangan lebih dan sistem pembumian
Subjek : protection systems, surge voltage and grounding system
Lightning Arrester adalah suatu alat pengaman jaringan dan pengaman komponen listrik dari gangguan tegangan lebih yang biasanya diakibatkan oleh surja petir atau sambaran petir dan yang kedua diakibatkan oleh surja hubung atau pemutusan beban. Pada keadaan normal, Lightning Arrester berfungsi sebagai isolator, tetapi pada saat terjadi gangguan Arrester berfungsi menjadi konduktor yang menyalurkan tegangan lebih ke tanah melalui kabel grounding atau kawat tanah. Komponen dasar untuk memasang sistem proteksi tegangan lebih petir dan surja hubung antara lain Lightning Arrester, Penghantar grounding BC dan Batang ROD Tembaga. Nilai Pentanahan untuk memproteksi dari gangguan tegangan lebih tidak boleh melebihi dari 3Ω. Kata kunci: sistem proteksi, tegangan lebih dan sistem pembumian.
Deskripsi Alternatif :Lightning Arrester is a device network safety and safety electrical components from the usually more voltage disturbances caused by surja lightning or lightning strikes and the second caused by surja hyphen or disconnection of the load Innormal circumstances, Lightning Arrester serves as an insulator, but in the event of Arrester function disorder became more ducked voltage conductor to the ground via the cable grounding wire or ground. The basic components to install lightning surge voltage protection systems and surja hyphen, among others, Lightning Arrester, Conductor grounding Rod and Copper ROD BC. The value of Grounding to protect from interference voltage must not exceed more than 3Ω. Keywords: protection systems, surge voltage and grounding system.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Sunarto, S.T., M.Eng.
Pembimbing 2: Drs. Dwi Asmono, M.Pd., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN TA - 121321025.pdf
(758743 bytes)
File : BAB 1 - 121321025.pdf
(291593 bytes)
File : BAB 2 - 121321025.pdf
(469060 bytes)
File : BAB 5 - 121321025.pdf
(282851 bytes)