Path: Top > Tugas Akhir - D3 > Jurusan Teknik Konversi Energi > Program Studi Teknik Konversi Energi > 2014
Pengembangan Penggunaan Mikrokontroler Atmega8 Untuk Pengontrolan Dan Pemantauan Tekanan Pada Digester Biogas
The Development Of Microcontroller Atmega8 Using For Pressure Controlling And Monitoring On Biogas Digester
Tugas Akhir, 047 / 2014 / TENUndergraduate Theses from JBPTPPOLBAN / 2018-04-20 11:27:19
Oleh : Regia Erfawinanda - 111711025 (regiaerfawinanda@gmail.com)
Dibuat : 2018-04-20, dengan 4 file
Keyword : Tekanan, Pemantauan Tekanan, Katup Solenoid, Mikrokontroler, Atmega8, Terminal emulator
Subjek : Pressure, Pressure Monitoring, Solenoid Valve, Microcontroller, Atmega8,Terminal Emulator
Salah satu komponen penting dalam instalasi kompor biogas adalah indikator tekanan gas yaitu manometer U. Manometer U merupakan alat yang menampilkan besarnya tekanan pada instalasi biogas, diletakkan di dekat kompor sebagai indikator kandungan bahan bakar yang bisa digunakan untuk memasak. Pada penelitian ini dilakukan penggantian manometer U dengan otomatisasi solenoid valve yang diatur dengan menggunakan sistem kontrol on-off berbasis Atmega8. Sistem kontrol ini dirancang dengan MPX5100GP sebagai sensor tekanan yang terintegrasi dengan rangkaian sistem minimum berbasis mikrokontroller Atmega8. Pemeriksaan sensor dilakukan dengan range tekanan 4 kPa sampai dengan 9 kPa dan dapat dibuktikan bahwa karakteristik sensor sudah linier. Keluaran dari rangkaian tersebut berupa tampilan LCD (Liquid Crystal Display) sebagai petunjuk nilai tekanan dan kondisi saklar otomatis (relay) yang akan menggerakan solenoid valve. Set point ditentukan dengan rentang 5 kPa sampai dengan 6 kPa, sehingga katup solenoid terbuka pada saat tekanan mencapai 6 kPa dan menutup pada saat tekanan mencapai 5 kPa. Pengujian keseluruhan sistem dilakukan dengan menggunakan terminal emulator sebagai perekam data dengan tekanan rata-rata pada digester sebesar 4 kPa dan tekanan puncak sebesar 6 kPa. Kata kunci: Tekanan, Pemantauan Tekanan, Katup Solenoid, Mikrokontroler, Atmega8, Terminal emulator.
Deskripsi Alternatif :One of the most important component in biogas installation is manometer U as pressure detector. Manometer U is a component that show the value of biogas installation digester pressure, it is placed near the biogas stove as fuel indicator that can be used for cooking. The topic of this final project is replacing the manometer U to an automatic on-off controller using solenoid valve work based on Atmega8. This system is programmed with MPX5100GP as pressure sensor that has been integrated with minimum system based on microcontroller Atmega8. The sensor was checked by supplying pressure in range 4 kPa to 9 kPa and it has been proved that sensor output has been linear based on datasheet. The output from this circuit was display on an LCD that showed pressure value. The set point was set on programmed at range 4 kPa to 6 kP. The solenoid valve was opened when the pressure reached 6 kPa, and it closed when pressure decrease to 5 kPa. The experiment was undergone by using terminal emulator as data recorder with average pressure in digester wass 4 kPa and maximum pressure 6 kPa Keywords: Pressure, Pressure Monitoring, Solenoid Valve, Microcontroller, Atmega8,Terminal Emulator.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Sri Utami, S.ST., M.T.
Pembimbing 2: Purwinda Iriani, S.Si., M.Si., Editor: Erlin Arvelina
Download...
File : DAFTAR - 111711025.pdf
(577919 bytes)
File : BAB 1 - 111711025.pdf
(213124 bytes)
File : BAB 2 - 111711025.pdf
(410832 bytes)
File : BAB 5 - 111711025.pdf
(163063 bytes)