Rancang Bangun Modul Praktikum Rele Arus Lebih menggunakan Rele Siemens 7SJ600 Terprogram

Design and Build Practicum Module of Over Current Relay by Using Programmed Relay Siemens 7SJ600

Tugas Akhir, 031 / 2013 / TLI
Undergraduate Theses from JBPTPPOLBAN / 2017-05-12 12:48:32
Oleh : Ridho Ilham Fauzi - 101321061 (ridhoilham.fauzi@gmail.com)
Dibuat : 2017-05-12, dengan 4 file

Keyword : Gangguan antar fasa, Transformator, Program, Relai, OCR
Subjek : Interphase Fault, Transformers, Programed Relays, OCR

Keandalan sistem tenaga listrik dari pembangkit sampai dengan distribusi sangat diperlukan baik oleh pelanggan maupun pemasok tenaga listrik, namun keandalan tersebut sulit untuk diwujudkan karena sering terjadinya gangguan-gangguan pada sistem jaringan distribusi listrik. Gangguan tersebut dapat merusak transformator sebagai akibat dari mengalirnya arus gangguan yang melebihi arus nominalnya. Maka untuk mengamankan transformator dari gangguan antar fasa perlu dipasang sistem proteksi Over Current Relay (OCR) untuk mengamankan dari arus lebih sehingga transformator tidak mengalami kerusakan walau terjadi gangguan arus lebih antar fasa. Relay terprogram Siemens 7sj600 yang mempunyai beberapa karakteristik seperti normal inverse, very inverse, extremely inverse and long time inverse digunakan didalam proyek akhir berupa pembuatan rancang bangun modul praktikum relay arus lebih. Dari hasil pengujian karakteristik waktu-arus dan simulasi setting hubung singkat pada simulator jaringan distribusi tenaga listrik serta dilengkapi dengan data-data yang diperoleh kemudian dianalisa, menunjukan bahwa relay tersebut masih mempunyai akurasi yang baik. Kata Kunci: Gangguan antar fasa, Transformator, Program, Relai, OCR.

Deskripsi Alternatif :

The reliability of electrical power system from the power station until the distribution is very important either for costumers or the electrical energy supplier. It is hard to realize that reability, because of the problems in electrical distribution system. The problems occurred in distribution system may be caused by the thunder or the branch of tree which hits the wire network. This trouble will flowing fault current that exceed nominal current of transformer. So that it is necessary to protect transformer from this fault by installed an over current relay. Programmed relay Siemens 7sj600 that has some kind of current-time characteristic like normaly inverse , very inverse , extremely inverse and long time inverse characteristics is using in final project to design and build practical module over current relay. From testing of current-time characteristic and simulation of short circuit setting on simulator of feeder electrical power distribution completed with datas analizing indicates that this relay still have good accuracy. Keywords: Interphase Fault, Transformers, Programed Relays, OCR.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Supriyanto, S.T., M.T.

    Pembimbing 2: Drs. Dwi Asmono, M.Pd., Editor: Erlin Arvelina

Download...