Uji Performansi Sistem Refrigerasi Mini Brine Cooling Dengan Propylene Glycol Sebagai Refrigeran Sekunder Untuk Pembuatan Es Krim
Performance Test Of Mini Brine Cooling Refrigeration System With Propylene Glycol As Secondary Refrigerant For Making Ice Cream
Tugas Akhir, 022 / 2014 / RTUUndergraduate Theses from JBPTPPOLBAN / 2018-04-03 15:33:48
Oleh : Rijal Quatussalam - 111611060 (rijaljay12@gmail.com)
Dibuat : 2018-04-03, dengan 4 file
Keyword : Indirect Expansion, Brine Cooling, Propylene Glycol
Subjek : Indirect Expansion, Brine Cooling, Propylene Glycol
Proses pendinginan tidak langsung atau indirect expansion adalah proses pendinginan dimana koil tidak langsung mendinginkan beban atau ruangan, tetapi terlebih dahulu mendinginkan fluida sebagai refrigerant sekunder, lalu fluida tersebut menyerap kalor dari beban yang akan didinginkan. Sistem refrigerasi kompressi uap dengan indirect expansion atau yang selanjutnya disebut sistem brine cooling. Tujuan dari penelitian pada tugas akhir ini adalah untuk menguji dan menganalisis karakteristik sistem mini brine cooling yang dirancang, sehingga dapat mengetahui sejauh mana pendinginan dapat dicapai dan faktor apa saja yang mempengaruhi perubahan karakteristik hasil yang dapat diperoleh. Jenis brine yang digunakan adalah propylene glycol dengan konsentrasi 70,6% air dan 29,4% propylene glycol dan refrigeran primer yang digunakan adalah R-134a dan kapasitas kompresor yang digunakan sebesar 1/3 HP. Selanjutnya analisis dilakukan dengan mengambil data seperti temperatur kabin, tekanan suction, temperatur dicharge, tekanan discharge, temperatur suction, temperatur brine, temperatur keluar kondenser, arus listrik, tegangan. Kemudian dilakukan pengolahan terhadap data-data tersebut sehingga mendapatkan kesimpulan berupa hasil kinerja sistem yang terbaik. Chilling time brine untuk mencapai -15⁰C selama 150 menit, temperatur kabin terandah yaitu -8⁰C, temperatur produk (es krim) terendah mencapai -2,88⁰C, dan memiliki periode cut off selama 700 menit selama 840 menit yang tersedia. COPaktual rata-rata untuk sistem ini adalah 2,28 dan efisiensi rata-rata sebesar 50,75%. Kata kunci: Indirect Expansion, Brine Cooling, Propylene Glycol.
Deskripsi Alternatif :Indirect expansion is a cooling process where the coil is not directly cool the load or the room, but formerly cools the fluid as the secondary refrigerant, and that fluid absorbs the heat from the load to be cooled. Vapor compression refrigeration system with indirect expansion or hereinafter will be called brine cooling system. The purpose of the research in this thesis is to examine and analyze the characteristics of mini brine cooling system designed, so as to determine the extent of cooling that can be achieved and what are the factors that influence the changes in the characteristics of the results that can be obtained. Type of brine used in the research is propylene glycol at a concentration of 70,6% water and 29,4% propylene glycol and primary refrigerant used is R-134a and compressor capacity used is by third HP. Furthermore, the analysis is done by taking the data such as cabin temperature, suction pressure, discharged temperature, discharged pressure, suction temperature, brine temperature, condenser exit temperature, electric current, and voltage. Then the data is processed so that the conclusion is the best system performance results. Chilling time brine to reach -15⁰C for 150 min, the lowest cabin temperature is -8⁰C, the lowest temperature of the product (ice cream) is -2.88⁰C, and has a cut-off period for 700 minutes during the available 840 minutes. Average actual COP of this system is 2,28 and average efficiency is 50,75%. Keywords: Indirect Expansion, Brine Cooling, Propylene Glycol.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Cecep Sunardi, S.T., M.Eng.
Pembimbing 2: Ir. Sumeru, M.T., Ph.D., Editor: Erlin Arvelina
Download...
File : DAFTAR - 111611060.pdf
(843135 bytes)
File : BAB 1 - 111611060.pdf
(268532 bytes)
File : BAB 2 - 111611060.pdf
(555390 bytes)
File : BAB 5 - 111611060.pdf
(253942 bytes)