ANALISIS PERFORMANSI SISTEM BRINE COOLING DENGAN VARIASI KONSENTRASI PROPYELEN GLYCOL –AIR SEBAGAI REFRIGERAN SEKUNDER

ANALYZE OF BRINE COOLING SYSTEM PERFORMANCE WITH CONSENTRATION VARIATIONS OF PROPYLENE GLYCOL AS SECONDARY REFRIGERANT

Tugas Akhir, 019 / 2012 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2014-07-04 08:53:49
Oleh : Rinard Perwira Kusnadi - 091611052 (kusnadirinard@gmail.com)
Dibuat : 2014-07-04, dengan 4 file

Keyword : Brine Cooling System, refrigeran, propylene glycol, coeficient of performance
Subjek : Global warming, refrigerant, Brine Cooling System, propylene glycol

Brine Cooling System adalah salah satu sistem refrigerasi yang menggunakan metode pendinginan tidak langsung, dimana proses pendinginanya menggunakan bantuan refrigeran sekunder. Brine Cooling System memiliki beberapa keutungan diantaranya penggunaan refrigeran primer yang lebih sedikit dibandingkan dengan sistem langsung, lebih meratanya proses pendinginan terhadap produk, disain untuk sistem refrigerasi primernya lebih kecil dan kompak dibandingkan dengan sistem pendinginan langsung dikarenakan dibandingkan dengan udara, air memiliki kapasitas termal yang lebih tinggi dibandingkan dengan udara. Pada tugas akhir ini dilakukan pengujian variasi propylene glycol sebagai refrigeran sekunder. Sistem Brine Cooling dibuat dan dianalisis dengan memvariasikan konsentrasi refrigeran sekunder 40% propylene glycol, 50% propylene glycol, dan 60% propylene glycol terhadap prestasi sistem refrigerasi yang dinyatakan dengan nilai coeficient of performance aktual dan konsumsi energinya. Dengan memvariasikan konsentrasi refrigeran sekunder maka nilai COPaktual yang dihasilkan sistem untuk konsentrasi 40% propylene glycol adalah 2.56, untuk konsentrasi 50% propylene glycol adalah2.56, sedangkan untuk konsentrasi 60% adalah 2.43. Dengan memvariasikan konsentrasi propylene glycol juga mempengaruhi terhadap nilai konsumsi daya pada setiap konsentrasinya, untuk konsentrasi 40% propylene glycol diperoleh 0.0325 kWH, untuk konsentrasi 50% propylene glycol diperoleh 0.0324 kWH sedangkan untuk konsentrasi 60% propylene glycol diperoleh 0.0266 kWH. Kata kunci: Brine Cooling System, refrigeran, propylene glycol, coeficient of performance

Deskripsi Alternatif :

The Brine Cooling system is one of part refrigeration system which use indirect expansion, where cooling process is helped by secondary refrigerant. The Brine Cooling System have many advantages, there are primary refrigerant is used less than direct expansion, design for primary refrigerant is more simply and more compact than direct expansion because if water is compared with air, thermal capacity of water higer than air. In this final project is done variantion test to propylene glycol as secondary refrigerant. Brine cooling system is made and analyzed with variant of concentration secondary refrigerant 40% propylene glycol, 50% propylene glycol and 60% propylene glycol to refrigeration system performance which is expresed by actual coeficient of performance and consumption energy influencet. With that system is varianting of concentration secondary refrigerant so the value COPactual is 2.56 for 40% propropylene glycol, 2.56 for 50% propylene glycol, and 2.43 for 60% propylene glycol. And from concentration variantion influence to energy consumption value is 0.0266 kWH for 60% propylene glycol, 0.0324 kWH for 50% concentration and 0.0325 for 40% propylene glycol. Key words: Global warming, refrigerant, Brine Cooling System, propylene glycol.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Triaji Pangripto Pramudantoro, ST., M.Eng.

    Pembimbing 2: Ir. Arda Rahardja Lukitobudi, M.Eng.
    , Editor: Erlin Arvelina

Download...