Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknologi Pembangkit Tenaga Listrik > 2018
Rancangan Heat Exchanger untuk Pendingin Hidrogen Pada C3W PLTU Kapasitas 600 MW
The Design of Heat Exchanger for Hydrogen Cooler at C3W 600 MW Steam Power Plant
Skripsi, 023 / 2018 / TPTLUndergraduate Theses from JBPTPPOLBAN / 2019-01-10 09:33:59
Oleh : Risma Fajar Rahayu - 141724027 (fajarrisma85@gmail.com)
Dibuat : 2019-01-10, dengan 4 file
Keyword : Heat exchanger Fin and tube C3W, Nilai Kekotoran, Penurunan tekanan, Efektivitas, mass flow
Subjek : Heat exchanger Fin and tube C3W, Dirtiness Value, Decrease, Effectiveness, mass flow
Heat exchanger Closed Circulating Cooling Water (C3W) merupakan salah satu komponen yang digunakan untuk sistem pendingin di generator. Heat exchanger Fin and Tube pada C3W merupakan teknologi alat penukar panas dengan penambahan sirip pada tube yang berfungsi untuk mendinginkan demin water yang telah mendingin hydrogen pada generator dengan menggunakan media sea water. Sirkulasi pada pendingin C3W merupakan siklus tertutup maka Heat exchanger dibutuhkan perannya untuk menjaga temperatur demin water tetap rendah yang akan mendinginkan generator. Fin and Tube Heat exchanger bekerja dengan cara cross-flow yaitu media pendingin sea water berada di dalam tube dan media yang akan didinginkan berada di dalam shell. Penambahan fin ini diharapkan dapat meningkatkan efektivitas pada heat exchangr C3W. Rancangan dimulai dengan menentukan kapasitas pendingin yang dibutuhkan pada sistem pendingin generator dengan menggunakan simulasi perangkat lunak ASPEN HYSYS. Langkah selanjutnya perhitungan neraca massa dan energi, dan parameter-parameter awal rancangan yaitu temperatur, laju alir massa, panas spesifik, konduktivitas thermal dan densitas dari demin water dan sea water. Besar panas yang harus diserap oleh demin water dan sea water sebesar 11,28 MWH atau 34Btu dari rugi total generator. Pemodelan matematika yang digunakan, berdasar pengembangan D.Q. Kern (1950). Spesifikasi tube yang digunakan menggunakan material ASTM B338 Titanium Grade 2 dengan diameter luar 38,1 mm, panjang tube 5548,579 mm, jumlah tube 24 buah dengan susunan triangular. Jumla fin 8 buah per inch, tinggi fin 18,796 mm tebal fin 2,9972 mm. Efektivitas yang dihasilkan sebesar 67%, dengan faktor kekotoran sebesar 0,001509 dan penurunan tekanan untuk sea water 5,92645 psi dan demin water 1,39951 psi. Dari hasil analisis bahwa kenaikan mass flow akan berdampak pada tekanan yaitu tekanan air laut dan juga demin water, semakin tinggi massflow maka tekanan semakin tinggi pula, dan sebaliknya semakin rendah massflow maka tenakanan akan semakin kecil/ rendah. Kata kunci: Heat exchanger Fin and tube C3W, Nilai Kekotoran, Penurunan tekanan, Efektivitas, mass flow.
Deskripsi Alternatif :Heat echanger Closed Circulating Cooling Water (C3W) is one of the components used for generator. Heat Exchanger Fin and Tube on C3W is a heat exchanger technology with the addition of fins on the tube that serves to cool the water demin that has cooled the hydrogen on the generator by using the sea water. Due to the circulation of C3W is a closed cycle, the fin and tube heat exchanger take its role to maintain the temperature of water demin remains low which will cool the generator. Fin and Tube Heat exchangers work in a cross-flow that the sea water is inside the tube and water demin to be cooled is inside the shell. The addition of these fins is expected to improve optimally on C3W heat exchangr. The design begins with measuring the required requirements of HYSYS ASPEN software simulation. The next step calculates mass and energy, and the initial production parameters are temperature, mass flow rate, specific heat, thermal conductivity and density of water demin and seawater. The amount of summer that must be absorbed by demin water and seawater is 11.28 MWH or 34Btu of total generator losses. Natural mathematical modeling,based on the development of D.Q. Kern (1950). Specification of tube using ASTM B338 Titanium Grade 2 material with outer diameter 38,1 mm, tube length 5548,579 mm, tube number 24 pieces with triangular arrangement. Total fin 8 pieces per inch, fin high 18,796 mm, long fins 2,9972 mm. The effectiveness is 70%, with the dirt factor calculations is 0.001509 and the pressure drop seawater 5,92645 psi and water demin 1,39951 psi. From the analysis that the increase of mass flow will affect the pressure drop of seawater and also demin water, the higher mass flow sea water, the higher also pressure drop needed. Keywords: Heat exchanger Fin and tube C3W, Dirtiness Value, Decrease, Effectiveness, mass flow.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Dr. Ir. Sri Wuryanti, M.Si.
Pembimbing 2: Drs. Ali Mashar, M.Eng.Sc., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN SKRIPSI - 141724027.pdf
(761297 bytes)
File : BAB 1 - 141724027.pdf
(103956 bytes)
File : BAB 2 - 141724027.pdf
(975317 bytes)
File : BAB 5 - 141724027.pdf
(96364 bytes)