Rancangan Transformator Daya Kapasitas 100 MVA 20/150 kV

Design of 100 MVA 20/150 kV Generator Transformer

Skripsi, 024 / 2018 / TPTL
Undergraduate Theses from JBPTPPOLBAN / 2019-01-10 09:36:33
Oleh : Rizal DarizKI - 141724028 (rizaldarizki13@gmail.com)
Dibuat : 2019-01-10, dengan 4 file

Keyword : perancangan generator transformer, efisiensi, arus inrush
Subjek : generator transformer design, efficiency, inrush current

Pada sistem tenaga listrik, transformator daya merupakan suatu komponen yang memegang peranan sangat penting. Generator transformer, selain berfungsi untuk menaikan tegangan menengah yang dibangkitkan oleh generator ke tegangan tinggi atau tegangan ekstra tinggi sistem transmisi, juga digunakan untuk mengurangi rugi-rugi daya pada saluran transmisi secara signifikan. Tujuan dari tugas akhir ini adalah untuk merancang sebuah transformator daya kapasitas 100 MVA, 20/150 kV, sebagai generator transformer. Tahapan perancangan mengacu pada standar PLN, IEC dan IEEE, juga pertimbangan teknis. Berdasarkan analisis hasil rancangan, transformator daya memiliki efisiensi 99,543% pada kondisi beban penuh dan faktor daya 0,8, dengan kerugian tanpa beban sebesar 39,186 kW dan kerugian beban penuh sebesar 328,117 kW. Efisiensi maksimum sebesar 99,717% terjadi pada kondisi 34,558% beban penuh. Arus puncak inrush dari transformator daya yang dirancang mencapai 750 A. Kata kunci: perancangan generator transformer, efisiensi, arus inrush.

Deskripsi Alternatif :

Power transformer is one important component of electric power system. A generator transformer usually used to convert medium output voltage of the generator into high or even extra high transmission voltage, thus reducing the power transmission losses. In this final project, a 100 MVA, 20/150 kV generator transformer is designed according to PLN, IEC, and IEEE standard, as well as technical consideration. Analysis shows that efficiency of the transformer is 99.543% on full load and 0.8 power factor conditions, with 39.186 kW no-load loss and 328.117 kW full-load loss. The highest efficiency is 99.717% when transformer is loaded 34.558% of its full load conditions. Further analysis shows that transformer inrush current is 750 A. Keywords: generator transformer design, efficiency, inrush current.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Dr. I Made Wiwit Kastawan, M.T.

    Pembimbing 2: Drs. Ali Mashar, M.Eng.Sc., Editor: Erlin Arvelina

Download...