Rancangan Transformator Daya Kapasitas 100 MVA 20/150 kV
Design of 100 MVA 20/150 kV Generator Transformer
Skripsi, 024 / 2018 / TPTLUndergraduate Theses from JBPTPPOLBAN / 2019-01-10 09:36:33
Oleh : Rizal DarizKI - 141724028 (rizaldarizki13@gmail.com)
Dibuat : 2019-01-10, dengan 4 file
Keyword : perancangan generator transformer, efisiensi, arus inrush
Subjek : generator transformer design, efficiency, inrush current
Pada sistem tenaga listrik, transformator daya merupakan suatu komponen yang memegang peranan sangat penting. Generator transformer, selain berfungsi untuk menaikan tegangan menengah yang dibangkitkan oleh generator ke tegangan tinggi atau tegangan ekstra tinggi sistem transmisi, juga digunakan untuk mengurangi rugi-rugi daya pada saluran transmisi secara signifikan. Tujuan dari tugas akhir ini adalah untuk merancang sebuah transformator daya kapasitas 100 MVA, 20/150 kV, sebagai generator transformer. Tahapan perancangan mengacu pada standar PLN, IEC dan IEEE, juga pertimbangan teknis. Berdasarkan analisis hasil rancangan, transformator daya memiliki efisiensi 99,543% pada kondisi beban penuh dan faktor daya 0,8, dengan kerugian tanpa beban sebesar 39,186 kW dan kerugian beban penuh sebesar 328,117 kW. Efisiensi maksimum sebesar 99,717% terjadi pada kondisi 34,558% beban penuh. Arus puncak inrush dari transformator daya yang dirancang mencapai 750 A. Kata kunci: perancangan generator transformer, efisiensi, arus inrush.
Deskripsi Alternatif :Power transformer is one important component of electric power system. A generator transformer usually used to convert medium output voltage of the generator into high or even extra high transmission voltage, thus reducing the power transmission losses. In this final project, a 100 MVA, 20/150 kV generator transformer is designed according to PLN, IEC, and IEEE standard, as well as technical consideration. Analysis shows that efficiency of the transformer is 99.543% on full load and 0.8 power factor conditions, with 39.186 kW no-load loss and 328.117 kW full-load loss. The highest efficiency is 99.717% when transformer is loaded 34.558% of its full load conditions. Further analysis shows that transformer inrush current is 750 A. Keywords: generator transformer design, efficiency, inrush current.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Dr. I Made Wiwit Kastawan, M.T.
Pembimbing 2: Drs. Ali Mashar, M.Eng.Sc., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN SKRIPSI - 141724028.pdf
(535616 bytes)
File : BAB 1 - 141724028.pdf
(323387 bytes)
File : BAB 2 - 141724028.pdf
(458942 bytes)
File : BAB 5 - 141724028.pdf
(131906 bytes)