Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknologi Pembangkit Tenaga Listrik > 2018

Rancangan Water Circulating Pump Pada Boiler Tipe Double Suction Untuk PLTU Kapasitas 625 MW

The Design of Water Circulating Pump in Boiler with Double Suction for Steam Power Plant Capacity 625 MW

Skripsi, 025 / 2018 / TPTL
Undergraduate Theses from JBPTPPOLBAN / 2019-01-10 09:39:56
Oleh : Rizal Sakirin Pauji - 141724029 (rizalsakirinpauji@gmail.com)
Dibuat : 2019-01-10, dengan 4 file

Keyword : PLTU, boiler sirkulasi paksa, pompa isapan ganda, titik operasi
Subjek : steam power plant, forced circulation boiler, double suction pump, operate point

Boiler merupakan komponen inti dalam Pembangkit Listrik Tenaga Uap (PLTU) yang berfungsi untuk mengubah fasa cair menjadi fasa uap yang bertekanan dan bersuhu tinggi. Boiler untuk menghasilkan listrik berkapasitas 625 MW membutuhkan pompa sirkulasi atau Water Circulating Pump yang berfungsi untuk mensirkulasikan fasa cair hasil pemisahan dari steam drum ke riser sehingga boiler ini disebut dengan boiler jenis sirkulasi paksa. Pompa pada dasarnya digunakan untuk menaikkan tekanan dan memindahkan fluida cair, dimana dalam rancangan ini juga pompa digunakan untuk mempertahankan aliran fluida cair agar mampu membangkitkan listrik berkapasitas besar yaitu 625 MW. Pompa yang dirancang adalah pompa sentrifugal satu tingkat dengan jenis isapan ganda. Pada rancangan ini dimulai dari pemodelan siklus PLTU menggunakan software Gate Cycle dengan menentukan parameter awal yaitu tekanan, suhu, dan laju alir massa. Besarnya masing-masing parameter pada sisi masukan tersebut adalah 194,703 bar, 363,506°C, dan 551,559 kg/s sedangkan parameter pada sisi keluaran adalah 198,703 bar, 364,187°C, dan 551,559 kg/s. Langkah selanjutnya dari parameter tersebut dilakukan perhitungan dasar untuk menentukan head total dan NPSHr agar tidak lebih besar dari NPSHa. Besarnya masing-masing parameter tersebut adalah 59,10 m dan 13 m < 40,96 m. Kemudian langkah selanjutnya adalah merancang komponen inti pompa, yaitu impeller, casing, shaft, dan bearing dimana bahan yang dipilih untuk komponen tersebut disesuaikan dengan standarisasi penggunaan. Sehingga berdasarkan hasil rancangan dan analisis yang dilakukan, Water Circulating Pump akan dapat beroperasi maksimum pada laju alir volume 1,089 m3/s dengan head 60,995 m dan besar efisiensi sebesar 86% dengan besar daya hidrolis sebesar 332,83 kW. Kata kunci: PLTU, boiler sirkulasi paksa, pompa isapan ganda, titik operasi.

Deskripsi Alternatif :

Boiler is a main component in steam power plant for changing fluid from liquid phase to vapor phase which has high pressure and temperature. Boiler which produces electricity with 625 MW as the capacity, need circulation pump or Water Circulating Pump that is used for circulating liquid phase which is the result of separation from steam drum to riser, so that this boiler can be called as forced circulation boiler. Basically, pump is used for increasing pressure and moving liquid fluid, in this design pump is also used for keeping liquid fluid flow so that it can generate electricity with 625 MW as the capacity. Design pump is one stage centrifugal pump with double suction. This design is starting from modeling steam power plant cycle using software Gate Cycle, with determinate certain parameter such as pressure, temperature, and mass flow. Each parameter in inlet side has value that is 194,703 bar, 363,506°C, and 551,559 kg/s while each parameter in outlet side has value that is 198,703 bar, 364,187°C, and 551,559 kg/s. Next step is doing basic calculation for determining total head and NPSHr so it want not be bigger than NPSHa. The value of each parameter are 59,10 m and 13 m < 40,96 m. Then next step is designing main component of pump, which is impeller, casing, shaft, and bearing that use selected material based on their using standard. Based on the result of design and analysis, water circulating pump can be operated at volume flow 1,089 m3/s as its maximum with 60,995 m head, 86% as the efficiency, and 332,83 kW as hydraulic power. Keywords: steam power plant, forced circulation boiler, double suction pump, operate point.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ika Yuliyani, S.T., M.T.

    Pembimbing 2: Drs. Maridjo, M.T., Editor: Erlin Arvelina

Download...