Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknik Konservasi Energi > 2019

Rancangan AQC dan PH Boiler pada Sistem Waste Heat Recovery Power Generation Industri Semen

The Design of AQC and PH Boiler in Waste Heat Recovery Power Generation System in Cement Industry

Skripsi, 027 / 2019 / TKE
Undergraduate Theses from JBPTPPOLBAN / 2019-12-12 12:41:48
Oleh : Rizky Adi Firdaus - 151734028 (rizky.adi.f97@gmail.com)
Dibuat : 2019-12-12, dengan 4 file

Keyword : Air Quenching Cooler, Ekonomiser, Emisi, Evaporator, Energi Listrik, Industri Semen, Superheater, Suspension Preheater, Themoflex, Waste Heat Recovery Power Generation (WHRPG)
Subjek : Air Quenching Cooler, Cement Industry, Economizer, Emition, Evaporator, Electrical Energy, Superheater, Suspension Preheater, Themoflex, Waste Heat Recovery Power Generation (WHRPG)

PT Holcim Indonesia, Tbk (Cilacap Plant) memproduksi semen dengan kapasitas produksi 7.800 ton/hari. Penggunaan energi listrik untuk memproduksi semen di PT Holcim Indonesia Tbk Pabrik Cilacap sebesar 74% atau 99,62 kWh/ton dan penggunaan energi thermal sebesar 26% atau 29,34 kWh/ton, hal ini menunjukkan bahwa penggunaan energi paling banyak adalah pada sisi kelistrikan. Hal tersebut perlu dilakukan upaya penghematan energi yang salah satunya dengan pemanfaatan gas buang panas (waste heat gas) dari Suspension Preheaeter dan Air Quenching Cooler. Keluaran gas buang panas dari kedua proses tersebut dapat digunakan sebagai sumber panas untuk sistem Waste Heat Recovery Power Generation (WHRPG) untuk membangkitkan sejumlah energi listrik. WHRPG yang digunakan pada penelitian ini menggunakan desain dari Kawasaki yang menggunakan tiga Turbin yang terpasang secara seri dan dua Flush Tank. Pemodelan pada WHRPG dilakukan dengan menggunakan software Thermoflex dan menghasilkan nilai daya listrik kotor (gross power) sebesar 5,547 MW dengan daya listrik bersih (net power) sebesar 4,114 MW. Rancangan Unit AQC Boiler mewakili desain dari sistem WHRPG sebagai alat penukar panas untuk menghasilkan uap superheat, unit ini terdiri dari komponen Ekonomiser, Evaporator dan Superheater. Setelah dilakukan perancangan maka akan didapat dimensi-dimensi seperti diameter pipa, panjang pipa serta jumlah pipa dari setiap komponen yang telah memenuhi kelayakan secara termal dan mekanik. Setelah mendapatkan dimensi dari susunan komponen-komponen maka didapat dimensi saluran (duct) dari AQC Boiler dengan tinggi 7,65 m, lebar 3 m dan panjang 10 m. Estimasi penghematan energi listrik dalam satu tahun setelah pemasangan WHRPG di PT Holcim Indonesia, Tbk (Cilacap Plant) sebesar 36,4 % dari total konsumsi energi listrik secara keseluruhan atau sebesar 28.495,34 MWh/tahun dan dapat menghemat emisi CO2 tidak langsung sebesar 23.936 ton CO2/tahun. Kata kunci: Air Quenching Cooler, Ekonomiser, Emisi, Evaporator, Energi Listrik, Industri Semen, Superheater, Suspension Preheater, Themoflex, Waste Heat Recovery Power Generation (WHRPG).

Deskripsi Alternatif :

PT Holcim Indonesia, Tbk (Cilacap Plant) produces cement with a production capacity of 7,800 tons/day. The use of electrical energy to produce cement at PT Holcim Indonesia Tbk Cilacap Factory by 74% or 99.62 kWh/ton and the use of thermal energy by 26% or 29.34 kWh/ton, this shows that the most energy use is on the electricity side. This is an opportunity to save energy, the ones of to improve energy consumption is the installation utilization of waste heat gas from Suspension Preheater and Air Quenching Coolers. The heat exhaust gas output from the two processes can be used as a heat source for the Waste Heat Recovery Power Generation (WHRPG) system to generate a certain amount of electrical energy. The WHRPG used in this study uses a design from Kawasaki that uses three series installed Turbines and two Flush Tanks. Modeling on WHRPG is done using Thermoflex software and produces a gross power value of 5.547 MW with a net power of 4.114 MW. The design of the AQC Boiler Unit represents the design of the WHRPG system as a heat exchanger to produce superheat vapors, this unit consists of Economizer, Evaporator and Superheater components. After the design is carried out, dimensions will be obtained such as pipe diameter, pipe length and the number of pipes from each component that has met the thermal and mechanical feasibility. After obtaining the dimensions of the arrangement of the components the duct dimensions of the AQC Boiler are obtained with a height of 7.65 m, a width of 3 m and a length of 10 m. Estimated electricity savings in one year after the WHRPG installation at PT Holcim Indonesia, Tbk (Cilacap Plant) amounted to 36.4% of the total electricity consumption or 28,495.34 MWh / year and could save indirect CO2 emissions of 23,936 tons CO2/year. Keywords: Air Quenching Cooler, Cement Industry, Economizer, Emition, Evaporator, Electrical Energy, Superheater, Suspension Preheater, Themoflex, Waste Heat Recovery Power Generation (WHRPG).

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ir. Teguh Sasono, M.T.

    Pembimbing 2: Ratu Fenny Muldiyani, S.Si., M.Si., Editor: Erlin Arvelina

Download...