PEMBUATAN DAN PENGUJIAN KOLEKTOR SURYA PLAT DATAR DUA KACA MENGGUNAKAN ISOLASI KAPUK
MANUFACTURING AND TESTING OF FLAT PLATE SOLAR COLLECTOR TWO GLASSES USING KAPOK TREE INSULATION
Tugas Akhir, 002 / 2012 / TENUndergraduate Theses from JBPTPPOLBAN / 2017-04-11 10:03:22
Oleh : Rizky Pandu Wiguna - 091711058 (iki.pandu@yahoo.com)
Dibuat : 2014-07-17, dengan 4 file
Keyword : Kolektor Surya, Isolasi Kapuk, ASHRAE 9397, Efisiensi
Subjek : Solar Collector, Kapok Tree Fiber Insulation, ASHRAE 9397, Efficiency
Salah satu sumber energi yang melimpah di Indonesia adalah energi matahari. Pemanfaatan sederhana dari energi matahari adalah sebagai sumber energi pada pemanas air surya. Untuk memanfaatkan energi matahari tersebut dibutuhkan sebuah kolektor surya. Kolektor surya tersebut menyerap energi radiasi dari matahari dan mengkonversikannya menjadi panas pada pipa-pipa air. Penggunaan dua buah kaca penutup pada kolektor surya bertujuan untuk mencegah panas yang diterima kolektor dari matahari tidak hilang ke lingkungan pada bagian atas kolektor. Penggunaan isolasi kapuk pada bagian bawah pelat penyerap bertujuan untuk mencegah panas pada pelat penyerap tidak hilang ke lingkungan. Pengujian untuk mengetahui efisiensi kolektor berpatokan pada standar ASHRAE 93-97 dan dilakukan mulai pukul 10.00 sampai pukul 14.00 dengan periode pengambilan data selama 15 menit. Dari hasil penelitian diketahui bahwa efisiensi kolektor surya dipengaruhi oleh intensitas radiasi matahari yang mengenai kolektor, temperatur air masuk dan temperatur air keluar. Efisiensi tertinggi yang dicapai oleh kolektor surya yang dibuat adalah sebesar 64,27% dengan temperatur air keluar sebesar 51,6°C. Kata Kunci : Kolektor Surya, Isolasi Kapuk, ASHRAE 9397, Efisiensi
Deskripsi Alternatif :One of the largest energy source in Indonesia is solar energy. The simple utilisation of solar energy as an energy source on the solar water heater. To make use of solar energy would require a solar collector. The solar collectors absorb radiant energy from the Sun and convert them into heat on water pipes. Use two pieces of glass cover on solar collector aims to prevent the heat from a solar collector are received is not lost to the environment at the top of the collector. The use of kapok tree fiber insulation on the bottom of the absorbent plate aims to prevent heat in absorbent plate is not disappear in to the environment. Testing to determine the efficiency of the collector based on ASHRAE standard 93-97 and carried out starting at 10: 00 a.m. until 2: 00 pm with a period of data retrieval for 15 minutes. From the results of the study revealed that the efficiency of a solar collector is affected by the intensity of the solar radiation on the collector, water temperature in and water temperature out. Highest efficiency reached by solar collector is 64,27% with water temperature out of 51.6°C. Key Words : Solar Collector, Kapok Tree Fiber Insulation, ASHRAE 9397, Efficiency
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Drs. Maridjo, MT.
Pembimbing 2: Ika Yuliyani, MT.
, Editor: Erlin Arvelina
Download...
File : DAFTAR - 091711058.pdf
(471632 bytes)
File : BAB 1 - 091711058.pdf
(316995 bytes)
File : BAB 2 - 091711058.pdf
(667303 bytes)
File : BAB 5 - 091711058.pdf
(239473 bytes)