Modifikasi Tangki Water Cooled Condenser Pada AC Split Kapasitas 1 HP Untuk Pemanas Air

Water Cooled Condenser Tank Modification AC Split Of 1 HP Capacity For Water Heater

Tugas Akhir, 041 / 2014 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2018-04-20 08:44:31
Oleh : Rosdiana Hanifa - 111611027 (rosdiana.hanifa@gmail.com)
Dibuat : 2018-04-20, dengan 4 file

Keyword : AC Split, heat recovery, refrigeration, hot water
Subjek : Split air conditioner, heat recovery, refrigeration, hot water

AC Split dengan sistem kompresi uap merupakan peralatan tata udara domestik yang paling banyak pemakaiannya. Pengeluaran kalor kondenser yang dibuang ke udara lingkungan dapat mencapai empat kali dari masukan daya kompresi. Pembuangan energi secara sia-sia akan mengurangi persediaan sumber daya energi konvensional. Pemanfaatan ulang energi menjadi energi dalam bentuk yang lain akan meminimalkan pembuangan energi dan meningkatkan efisiensi total sistem. Temperatur refrigeran keluar kondenser dapat mencapai 50⁰C tergantung pada kondisi udara ambien. Energi buangan kondenser dapat dimanfaatkan untuk preheating atau pemanasan awal fluida yang lain seperti air. Pemanfaatan energi kalor untuk pemanasan air akan menambah nilai tambah berupa penggunaan energi pemanasan air menjadi lebih kecil. Pada Tugas Akhir ini dilakukan penelitian untuk memodifikasi sistem pemanas air pada AC Split dengan tangki terbuka menjadi sistem tangki tertutup. Hasil yang didapat menunjukkan COP aktual sistem sebesar 2,815, COP carnot 4,52 dan efisiensi sistem mencapai 62,2% dengan temperatur air mencapai 45,2⁰C. Kata kunci: AC Split, heat recovery, refrigeration, hot water.

Deskripsi Alternatif :

Split air conditioner with a vapor compression system is the most widely used in domestic air system equipment. Heat of condenser discharged into ambient air can reach four times the compression input power. Disposal of useless energy that will reduce the supply of conventional energy resources. Reuse in the form of energy into another energy will minimize the waste of energy and improve the efficiency of the total system. Temperature refrigerant out of condenser can reach 50⁰C depending on ambient air conditions. Exhaust energy of condenser can be utilized for preheating a fluid such as water. Utilization of heat energy for heating the water would be add the value in the form of water heating energy usage becomes smaller. In this final project conducted research to modify the water heating system on the AC Split with open tank into a closed tank system. The results obtained indicate COP the actual system is 2,815, COP carnot 4,52 and the efficiency of system reaches 62.2% with the water temperature reaches 45.2⁰C. Keywords: Split air conditioner, heat recovery, refrigeration, hot water.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Nur Khakim, S.T., M.Sc.


    Pembimbing 2: Markus, S.T., M.T., Editor: Erlin Arvelina

Download...