Path: Top > Tugas Akhir - D3 > Jurusan Teknik Refrigerasi dan Tata Udara > Program Studi Teknik Refrigerasi dan Tata Udara > 2014

Kaji Eksperimental Dan Analisis Performansi Mesin Cool-Box Dengan Variasi Adjustable Screw Katup Ekspansi Termostatik

Experimental Examination And Performance Analysis Cool-Box Machine Through Adjustable Screw Thermostatic Expansion Valve Variation

Tugas Akhir, 004 / 2014 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2018-04-04 15:41:48
Oleh : Rury Desti Iryanty - 111611028 (rurydesti@gmail.com)
Dibuat : 2018-04-04, dengan 4 file

Keyword : Sistem Refrigerasi, TXV, konsumsi energi, mesin cool-box
Subjek : Refrigeration System, TXV, energy consumption, cool-box machine

Sistem refrigerasi sangat dibutuhkan dalam kehidupan sehari-hari baik untuk keperluan rumah tangga, komersial dan industri. Sistem refrigerasi yang biasa dibutuhkan untuk penyimpanan bahan-bahan makanan maupun minuman yang memerlukan kondisi dingin dengan menggunakan sistem refrigerasi sederhana yaitu sistem refrigerasi kompresi uap. Mesin refrigerasi cool-box dapat mendinginkan berkisar 1⁰C s/d -5⁰C. Salah satu komponen dalam sistem refrigerasi ini yang berfungsi untuk mengatur jumlah refrigeran cair yang memasuki evaporator sesuai dengan beban pendinginannya yaitu katup ekspansi TXV (Thermostatic Expansion Valve). Tujuan dari pengkajian ini adalah untuk mendapatkan mesin refrigerasi cool-box yang lebih hemat energi. Pada penelitian ini dikaji variasi bukaan katup ekspansi TXV serta pengaruhnya terhadap performansi mesin cool-box ketika katup ekspansi TXV dalam keadaan normal, diputar 45⁰ dan 90⁰ searah jarum jam. Ketika katup ekspansi diputar 90⁰ searah jarum jam mesin cool-box dapat mengkonsumsi 0.7 kWh sistem mengalami 3 kali cut-in dan cut-out terjadi selama 347 menit dengan off cycle selama 17,3 jam/hari. Ketika katup ekspansi TXV diputar 45⁰ searah jarum jam memiliki efisisiensi kerja tertinggi sebesar 77,4% dan mengkonsumsi energi sebesar 0.9 kWh terjadi selama 332 menit, Hasil dari pengkajian ini adalah sistem yang menggunakan katup ekspansi TXV diputar 90⁰ searah jarum jam lebih kecil mengkonsumsi energi sehingga mesin ini akan hemat energi, meskipun katup ekspansi TXV yang diputar 45° searah jarum jam memiliki efisisiensi kerja baik. Kata Kunci: Sistem Refrigerasi, TXV, konsumsi energi, mesin cool-box.

Deskripsi Alternatif :

The refrigeration systems are needed in daily life for example household, commercial and industrial. Refrigeration system which usually needed is a storage of materials such as foods or beverages that requires cold condition by using a simple vapor compression-refrigeration. Refrigeration cool-box has a cooling range at 1⁰C to -5⁰C. Component in the refrigeration system that serves to regulate the amount of flow of liquid refrigerant entering the evaporator accordance with cooling load at evaporator is a TXV (Thermostatic Expansion Valve). The purpose of this investigation is to obtain a cool-box refrigeration machine which can reduce energy consumption. This investigation was examined the variation of screw of TXV and the influence into the system. The examination shows the performance of the cool-box when the TXV are in normal condition, rotated into 45 degrees and 90 degrees clockwise. When the screw of TXV rotated into 90 degrees clockwise, the cool box machine consumed energy up to 0,7 kWh and the system got cut-in and cut-out which occurred for 347 minute and it could maintain the cabin temperature until 17,3 hours per day. When the screw of TXV was rotated into 45 degrees clockwise had a good efficiency up to 77,4% and consumed energy up to 0,9 kWh which occurred for 332 minute. The results of this investigation reveals that the system which uses expansion valve thermostatic rotated 90 degrees clockwise is less consuming energy compare to the TXV which is rotated 45 degrees clockwise has a good efficiency 77,4%. Keywords: Refrigeration System, TXV, energy consumption, cool-box machine.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Cecep Sunardi, S.T., M.Eng.

    Pembimbing 2: Triaji Pangripto Pramudantoro, S.T., M.Eng., Editor: Erlin Arvelina

Download...