Perancangan Sistem Tata Udara Mobil Pada Isuzu Elf di PT FRIGIA Air Conditioning
The Assembling of Car Air Conditioning System for Isuzu Elf at PT FRIGIA Air Conditioning
Tugas Akhir, 002 / 2012 / RTUUndergraduate Theses from JBPTPPOLBAN / 2014-06-19 13:03:38
Oleh : Santi Azizah - 091611027 (aziezah.santie@gmail.com)
Dibuat : 2014-06-19, dengan 4 file
Keyword : Beban pendinginan, Isuzu Elf, Kompresor
Subjek : Cooling load, Isuzu Elf, Compressor
Setiap manusia selalu menginginkan kondisi yang nyaman dimana ia berada, tidak hanya di dalam ruangan tempat bekerja tetapi juga pada alat transportasi yang sekarang sudah menjadi kebutuhan yang sangat penting. Dibutuhkan adanya perhitungan beban pendinginan kemudian dipilih komponen yang dipasang sesuai dengan beban pendinginan dari mobil. Tujuan tugas akhir ini adalah untuk menghitung beban pendinginan dan untuk menentukan alat yang diperlukan untuk Isuzu Elf. Pengumpulan data dilakukan dengan pengolahan perhitungan beban pendinginan eksternal dan internal untuk mendapatkan keuntungan panas masuk akal, laten dan total kemudian memilih peralatan yang diperlukan untuk Isuzu Elf. Hasil dari tugas akhir ini adalah bahwa kapasitas pendinginan total yang diperoleh adalah 29333.76 Btu / jam dan kompresor dibutuhkan adalah model 10P15C dengan kapasitas pendinginan nominal adalah 8.62 kW. Kata kunci : Beban pendinginan, Isuzu Elf, Kompresor
Deskripsi Alternatif :Every human always wants to has a comfortable condition in every moment which a person live, not only in the room when they work but also on the transportation become the most important requirement. It takes from the cooling load calculation then be select the components are install in accordance with the cooling load. The aim of the final project is to calculate the cooling loads and determine which is tools are needed for Isuzu Elf. Data collection was conducted by a processing of cooling load calculation of external and internal to obtain the sensible, latent and total heat gain then choosing tools needed for Isuzu Elf. The result of the final project are that the total cooling capacity obtained is 29333.76 Btu/hr and compressor needed is a model of 10P15C with a nominal cooling capacity is 8.62 kW. Keywords : Cooling load, Isuzu Elf, Compressor
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Ade Suryatman Margana, ST., M.Eng.
Pembimbing 2: Ir. Andriyanto Setyawan, MT. , Editor: Erlin Arvelina
Download...
File : DAFTAR - 091611027.pdf
(442268 bytes)
File : BAB 1 - 091611027.pdf
(173794 bytes)
File : BAB 2 - 091611027.pdf
(458377 bytes)
File : BAB 6 - 091611027.pdf
(162767 bytes)