Analisis Rancangan Kualitas Daya Listrik Pada PLTPH Dengan Beban Ballast
Design Analysis Of Electricity Quality in PicoHidro-Plant With Ballast Load
Skripsi, 023 / 2021 / TKEUndergraduate Theses from JBPTPPOLBAN / 2022-12-28 13:44:46
Oleh : Sembada Wangsadireja - 171734028 (sembada.wangsadireja.tken417@polban.ac.id)
Dibuat : 2022-12-28, dengan 4 file
Keyword : Arus, Biner, IGC, Phase Angle, Harmonisa, dan PLTPH
Subjek : Current, Binary, IGC, Phase Angle, Harmonics and PLTPH
Dalam era saat ini listrik menjadi komponen yang sangat penting. Umumnya daerah pelosok belum terdapat pasokan listrik dari PLN, salah satu solusi untuk memenuhi kebutuhan listrik tersbut adalah dengan membuat PLTPH. Namun output dari PLTPH berupa tegangan, frekuensi, dan harmonisa masih belum memenuhi standar yang menimbulkan dampak negatif pada sisi pembangkit maupun konsumen. IGC (Induction Generator Controller) pada PLTPH merupakan sebuah alat untuk menstabilkan output dari generator dengan cara mengalihkan kelebihan daya yang tidak digunakan ke beban ballast. Pada penelitian ini digunakan motor induksi 1 fasa yang difungsikan sebagai generator berkapasitas 250 Watt dengan beban ballast load berupa beban biner dan phase angle. Beban ballast yang digunakan menggunakan metode biner dan metode phase angle. Kedua metode tersebut memiliki kelebihan dan kekurangan masing-masing, untuk kelebihan metode biner tidak menimbulkan harmonisa tetapi nilainya sudah di setting tetap (tidak bisa spesifik), sementara untuk metode phase angle nilainya spesifik namun menimbulkan efek harmonisa yang berdampak negatif pada sisi sumber dan juga konsumen. Untuk pemenuhan beban pada konsumen disesuaikan dengan jenis beban yang biasa dipergunakan yaitu beban resistif dan resistif-induktif. Karakteristik dari kedua beban tersebut berpengaruh terhadap generator dan efek harmonisa yang timbul. Berdasarkan hasil rancangan didapat nilai nilai THD arus pada beban resistif sebesar 0.47% - 1.35% dan THD tegangan sebesar 0.20% - 0.80%. Sedangkan pada beban resistif-induktif dihasilkan THD arus sebesar 0.57% - 1.42% dan THD tegangan sebesar 0.28% - 0.60%. Dari hasil analisis rancangan tersebut didapat nilai harmonisa yang memenuhi standar IEEE 559.1992. Kata kunci: Arus, Biner, IGC, Phase Angle, Harmonisa, dan PLTPH.
Deskripsi Alternatif :In today's era, electricity is a very important component. Generally, remote areas do not have electricity supply from PLN, one solution to meet the electricity needs is to make PLTPH. However, the output of PLTPH in the form of voltage, frequency, and harmonics still does not meet the standard which has a negative impact on the generator and consumer side. The IGC (Induction Generator Controller) in PLTPH is a tool to stabilize the output of the generator by diverting excess unused power to the ballast load. In this study, a single-phase induction motor was used which functioned as a generator with a ballast load in the form of a binary load and a phase angle. The ballast load used is the binary method and the phase angle method. Both methods have their respective advantages and disadvantages, for the advantages of the binary method it does not cause harmonics but the value has been set fixed (cannot be specific), while for the phase angle method the value is specific but causes harmonic effects which have a negative impact on the source and consumer side. . To fulfill the load on consumers, it is adjusted to the types of loads commonly used, namely resistive and resistive-inductive loads. The characteristics of the two loads affect the generator and the resulting harmonic effects. To fulfill the load on consumers, it is adjusted to the types of loads commonly used, namely resistive and resistive-inductive loads. The characteristics of the two loads affect the generator and the resulting harmonic effects. The current THD value for resistive load is 0.47% - 1.35% and the voltage THD is 0.20% - 0.80%. Meanwhile, the resistive-inductive load produces a current THD of 0.57% - 1.42% and a voltage THD of 0.28% - 0.60%. From the results of the analysis of the design obtained harmonic values that meet the IEEE 559.1992 standard. Keywords: Current, Binary, IGC, Phase Angle, Harmonics and PLTPH.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing: Ir. Wahyu Budi Mursanto, M.Eng., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN SKRIPSI - 171734028.pdf
(898476 bytes)
File : BAB 1 - 171734028.pdf
(204129 bytes)
File : BAB 2 - 171734028.pdf
(1293539 bytes)
File : BAB 5 - 171734028.pdf
(190386 bytes)