Path: Top > Tugas Akhir - D3 > Jurusan Teknik Refrigerasi dan Tata Udara > Program Studi Teknik Refrigerasi dan Tata Udara > 2012
Pengujian Kinerja Alat Destilasi Air Laut Penghasil Air dan Garam Menggunakan Sistem Refrigerasi Kompresi Uap
Performance Test of Sea Water Distillation to Produce Water and Salt Using Vapor Compression Refrigeration System
Tugas Akhir, 032 / 2012 / RTUUndergraduate Theses from JBPTPPOLBAN / 2015-11-18 09:21:40
Oleh : Septyan Yuswanto - 091611057
Dibuat : 2012-10-04, dengan 4 file
Keyword : destilasi, air bersih, garam, COP aktual dan efisiensi refrigerasi
Subjek : distillation, fresh water, salt, the actual COP and refrigeration efficiency
Laporan ini mengemukakan uji kinerja alat destilasi air laut menggunakan sistem refrigerasi kompresi uap dalam menghasilkan air tawar dan garam. Alat ini dibuat dalam rangka untuk mencari solusi alternatif terhadap masalah kurangnya air bersih bagi warga sekitar pantai dan mempercepat proses pemanenan garam. Pengujian kualitas air merujuk SNI 01-6241-2000 kategori air demineral. Standar tersebut memberi batasan mengenai kandungan maksimum komponen kimia, dan fisik yang dipersyaratkan untuk air tawar hasil destilasi (distilat). Pengujian dilakukan dengan membandingkan kualitas air antara sebelum proses destilasi dan setelahnya di Laboratorium Teknik Kimia Politeknik Negeri Bandung. Sampel air sebanyak 2 liter untuk pengujian parameter fisik dan kimia. Dari perbandingan nilai parameter tersebut dapat dievaluasi kualitas airnya. Pengujian juga untuk menentukan efisiensi alat destilasi dan jumlah air tawar yang dihasilkan per satuan waktu. Hasil pengujian diperoleh COP aktual 5,96 dan efisiensi refrigerasi 85 %. Hasil air selama 6 jam berjumlah 9,6 liter dari sumber air awal sebesar 15,98 liter dan menyisakan 2,84 liter. Kualitas distilat diperoleh pH 7, suhu air 26,3 0C, berasa tawar, tidak berbau, jernih, tidak ada endapan, DHL 0,014 mS/cm, TDS 10 mg/L dan kekeruhan 2,58 NTU. Distilat berguna untuk keperluan air bersih (mandi, cuci dan kakus) dan tidak dapat diminum. Kata Kunci : destilasi, air bersih, garam, COP aktual dan efisiensi refrigerasi.
Deskripsi Alternatif :This report suggests test sea water distillation equipment performance using the vapor compression refrigeration system to produce fresh water and salt. This tool is made in order to find an alternative solution to the problem of lack of clean water for residents around the coast and speed up the process of harvesting the salt. Water quality testing refers to the SNI 01-6241-2000 with demineralized water category. The standard is a limit on the maximum content of chemical components, physical and fresh water required for distillation.
The method is done by comparing the water quality before the distillation process and after at the Laboratory of Chemical Engineering Polytechnic Bandung. Water samples are needed as much as 2 liters for the measurement of physical and chemical parameters. From the comparison of parameter values can be evaluated water quality. Testing also to determine the efficiency of distillation equipment and the amount of fresh water produced per unit time.
The results of test are 5.96 of actual COP and the refrigeration efficiency is 85%. Results of water for 6 hours amounted to 9.6 liters from 15,98 liters source water and 2,84 liters is residual. The quality of the distillate obtained pH 7, water temperature 26.3 0C, tasteless tasteless, odorless, clear, no sediment, DHL 0.014 mS/cm, TDS 10 mg/L and turbidity 2.58 NTU, Useful for the purposes of distillate water (bathing, washing and latrine) and can not be drunk.
Keywords : distillation, fresh water, salt, the actual COP and refrigeration efficiency.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Ir. Windy Hermawan Mitrakusuma, MT.
Pembimbing 2: Ade Suryatman Margana, ST., M.Eng.
, Editor: Erlin Arvelina
Download...
File : DAFTAR - 091611057.pdf
(545368 bytes)
File : BAB 1 - 091611057.pdf
(387352 bytes)
File : BAB 2 - 091611057.pdf
(813090 bytes)
File : BAB 5 - 091611057.pdf
(903878 bytes)