Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknologi Pembangkit Tenaga Listrik > 2017
Rancangan Intercooler Tahap Pertama pada Kompresor Gas Torak Multistage untuk CNG Storage Plant Kapasitas 30 MMSCFD
Design of Multistage Reciprocating Gas Compressors First Stage Intercooler on 30 MMSCFD CNG Storage Plant
Tugas Akhir, 020 / 2017 / TPTLUndergraduate Theses from JBPTPPOLBAN / 2018-09-03 15:05:20
Oleh : Setiawan Akbar - 131724027 (setiawan.akbar@yahoo.com)
Dibuat : 2017-12-07, dengan 4 file
Keyword : CNG Storage Plant, kompresor, intercooler, Bell-Delaware
Subjek : CNG Storage Plant, compressor, intercooler, Bell-Delaware
CNG Storage Plant merupakan sebuah sistem untuk menyimpan gas dalam sebuah bejana bertekanan sebagai cadangan, sehingga gas tersebut dapat digunakan sewaktu-waktu diperlukan. Proses utama pada sistem CNG Storage Plant terdiri dari kompresi, pencairan dan dekompresi. Untuk dapat mengompresi gas sebelum disimpan dalam bejana bertekanan diperlukan kompresor dengan rasio kompresi tinggi, seperti kompresor gas torak multistage. Dalam proses kompresi terjadi peningkatan suhu sehingga diperlukan pendingin antara (intercooler) untuk mengatur agar suhu gas pada proses kompresi multistage tidak terjadi peningkatan suhu yang sangat tinggi. Dari hasil perhitungan kompresi tahap pertama, kalor yang harus dilepas pada pendingin intercooler agar suhu gas keluaran sama dengan suhu masukkan kompresor adalah sebesar 88,67 kJ/s. Dengan menggunakan metode Bell-Delaware didapat hasil rancangan intercooler dengan spesifikasi dimensi tube: panjang 1,829 m; diameter luar 0,019 m; diameter dalam 0,017 m; susunan segitiga; jumlah tube 176 buah; material berupa copper alloy (CuNi 90/10). Sedangkan untuk dimensi shell: panjang 1,829 m; diameter dalam 0,387 m; Schedule STD; baffle cut 20%; baffle space 0,116 m; jumlah baffle 13 buah; material berupa carbon steel. Hasil evaluasi kelaikan operasi menunjukkan bahwa rancangan intercooler pada proses kompresi tahap pertama telah laik operasi dengan heat transfer coefficient clean 217,65 W/m2.K, dirt factor r 3,18×10-4 m2.K/W, pressure drop sisi tube 6,08 kPa, pressure drop sisi shell 0,762 kPa. Kata kunci: CNG Storage Plant, kompresor, intercooler, Bell-Delaware.
Deskripsi Alternatif :The CNG Storage Plant is a system for storing gas in a pressure vessel as a reserve, so that it can be used whenever necessary. The main processes in the CNG Storage Plant system consist of compression, liquefaction and decompression. To compress the gas before it is stored in a pressure vessel, a compressor with a high compression ratio, such as a multistage piston gas compressor, is required. In the compression process there is a significant increase in temperature, so that it is required a cooling system in between (intercooler) to set the gas temperature outlet of the multistage compression process does not increase very high. From the first stage compression calculation result, the heat to be released on the intercooler in order to the gas temperature of compressor outlet equal to the gas temperature of the compressor inlet is 88.67 kJ/s. By using Bell-Delaware method, it is obtained the specification of intercooler design with tube dimension: length 1.829 m; Outside diameter 0.019 m; Inside diameter 0.017 m; Arrangement of triangles; Number of tube 176 pieces; Material of copper alloy (CuNi 90/10). As for the shell dimensions: length 1.829 m; Inside diameter 0.387 m; Schedule STD; Baffle cut 20%; Baffle space 0.116 m; Number of baffles 13 pieces; Material in the form of carbon steel. The results of feasibility operation showed that the intercooler design in the first stage compression process was feasible. Clean heat transfer coefficient is 217.65 W / m2.K, dirt factor is r 3,18×10-4 m2.K/W, pressure drop tube side is 6.08 kPa, and pressure drop in the shell side is 0.762 kPa . Keywords: CNG Storage Plant, compressor, intercooler, Bell-Delaware.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Bambang Puguh Manunggal, S.T., M.Eng.
Pembimbing 2: Dr. Ir. Ahmad Rifandi, M.Sc., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN TA - 131724027.pdf
(745901 bytes)
File : BAB 1 - 131724027.pdf
(104666 bytes)
File : BAB 2 - 131724027.pdf
(1108683 bytes)
File : BAB 5 - 131724027.pdf
(93356 bytes)