Karakteristik Reduksi Harmonisa Inverter PWM Natural Sampled Satu Fasa

Harmonic Reduction Characteristic of Single-phase Natural Sampled PWM Inverter

Tugas Akhir, 053 / 2014 / TEN
Undergraduate Theses from JBPTPPOLBAN / 2018-04-20 10:51:17
Oleh : Sri Novi Dayanti - 111711060 (sndnovi@gmail.com)
Dibuat : 2018-04-20, dengan 4 file

Keyword : inverter satu fasa setengah gelombang, teknik natural sampled PWM, frekuensi penyaklaran, kandungan harmonisa, dan rugi-rugi penyaklaran
Subjek : half-wave single-phase inverter, PWM natural sampled technique, switching frequency, harmonics content, switching losses

Laporan Tugas Akhir ini membahas pembuatan inverter satu fasa dengan teknik penyaklaran natural sampled PWM. Inverter ini memiliki rangkaian daya dengan tegangan masukan yang didapatkan dari hasil penyearahan sumber tegangan ac PLN yang diturunkan dengan trafo step-down. Inverter ini menggunakan dua buah MOSFET untuk membentuk struktur setengah jembatan. Rangkaian kendali PWM terdiri dari pembangkit gelombang referensi sinusoidal dan segitiga, rangkaian komparator, rangkaian inverting, rangkaian penguat dan rangkaian opto-coupler. Inverter PWM ini selanjutnya diuji untuk mendapatkan data kandungan harmonisa tegangan keluaran pada frekuensi penyaklaran yang berbeda yaitu , dan . Selain itu dilakukan juga pengujian untuk memperoleh data kenaikan temperatur MOSFET untuk menentukan karakteristik rugi-rugi penyaklarannya. Berdasarkan pengujian didapatkan hasil bahwa kandungan harmonisa tegangan keluaran tertinggi sebesar dan kenaikan temperatur saklar terendah yaitu 46,4 oC diperoleh pada frekuensi penyaklaran terendah yaitu . Sedangkan, frekuensi penyaklaran tertinggi didapatkan kandungan harmonisa tegangan keluaran terendah yaitu dan kenaikan temperatur saklar tertinggi yaitu 61,8 oC. lebih lanjut hasil simulasi menunjukkan bahwa kandungan harmonisa arus keluaran tertinggi sebesar diperoleh pada frekuensi penyaklaran terendah dan kandungan harmonisa arus keluaran terendah yaitu diperoleh saat inverter bekerja pada frekuensi penyaklaran tertinggi . Dengan demikian inverter PWM natural sampled satu fasa yang menunjukkan bahwa kandungan harmonisa tegangan dan arus keluaran akan semakin kecil jika frekuensi penyaklarannya semakin tinggi. Namun dengan frekuensi penyaklaran yang semakin tinggi, rugirugi penyaklaran inverter juga akan semakin besar. Kata kunci: inverter satu fasa setengah gelombang, teknik natural sampled PWM, frekuensi penyaklaran, kandungan harmonisa, dan rugi-rugi penyaklaran.

Deskripsi Alternatif :

This final project presents construction of a single-phase natural sampled PWM inverter. The inverter is supplied by a 15 V dc voltage source generated from rectification of a 220 V ac line voltage stepped down to 24 V ac by a 220/24 V transformer. The inverter uses two MOSFET static switches to form a half-bridge structure. Natural sampled PWM technique has been selected to control switching of the inverter. The PWM block circuit consists of a sinusoidal reference waveform generator, a triangular carrier waveform generator, comparator circuit, inverting circuit, amplifier circuit, and opto-coupler circuit. The inverter is tested to get its output voltage harmonics content under three different switching frequency, i.e. 300 Hz, 600 Hz, and 900 Hz. Temperature rise of the MOSFET is also measured to identify the switching losses characteristic of the inverter. Results of the test show that highest harmonics content about 11,86 Vand lowest MOSFET temperature about 46,4oCproduced when inverter is switched under the lowest frequency i.e. 300 Hz. Meanwhile under highest switching frequency, i.e. 900 Hz, inverter produces lowest output voltage harmonics content about 7,6 V and highest MOSFET temperature about 71,8 oC.Further, simulation results show that highest output current harmonics about 0,124 Ais produced by the lowest switching frequency i.e. 300 Hz while the lowest output current harmonics content about 0,054Ais produced by the highest switching frequency i.e. 900 Hz. Thus, the single-phase natural sampled PWM inverter shows a characteristic that the highest the switching frequency the lowest its output voltage and current harmonics content and the highest its switching losses. Keywords: half-wave single-phase inverter, PWM natural sampled technique, switching frequency, harmonics content, switching losses.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing: Dr. I Made Wiwit Kastawan, S.T., M.T., Editor: Erlin Arvelina

Download...