Path: Top > Skripsi - D4 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknologi Pembangkit Tenaga Listrik > 2018

Rancangan Plate Heat Exchanger Sebagai Pendingin Oli Pelumas Kapasitas 734 kW

Design of Plate Heat Exchanger as Lube Oil Cooler with Capacity of 734 kW

Skripsi, 002 / 2018 / TPTL
Undergraduate Theses from JBPTPPOLBAN / 2018-10-01 10:46:27
Oleh : Sulthaan Al Maulani - 131724029 (sulthaan.almaulani@gmail.com)
Dibuat : 2018-10-01, dengan 4 file

Keyword : Plate Heat Exchanger, jarak antar pelat, penurunan tekanan
Subjek : Plate Heat Exchanger, plates gap, pressure drop

Sebuah pembangkit listrik memiliki banyak komponen bergerak memerlukan sebuah perawatan salah satunya adalah pelumasan. Oli pelumas yang digunakan untuk kerja pada bantalan komponen tersebut perlu dijaga kondisinya terutama kondisi temperature, maka diperlukan sebuah pendingin oli pelumas untuk mendinginkan pelumas agar dapat digunakan kembali. Rancangan Plate Heat Exchanger dengan kapasitas perpindahan panas 734 kW dibuat sebagai alat pendingin oli pelumas dengan laju alir oli 60𝑚3/jam pada pembangkit listrik tenaga panas bumi. Dengan mengangkat analisa tentang penambahan jarak celah antar pelat, yang merupakan salah satu faktor penting dalam merancang sebuah PHE. Karya ilmiah ini mengkaji efek kenaikan jarak pelat terhadap area transfer panas total dan penurunan tekanan total. Dalam metode perhitungan rancangan jarak pelat divariasikan dan variabel lain diasumsikan konstan. Meningkatnya jarak pelat ini menambah luas area penampang dan diameter ekivalen, serta menurunkan kecepatan fluida pada saluran dan Reynold number. Sehingga terjadi penambahan luas perpindahan panas dan pengurangan penurunan tekanan. Kata kunci: Plate Heat Exchanger, jarak antar pelat, penurunan tekanan.

Deskripsi Alternatif :

A power plant has many moving components requiring a treatment, one of which is lubrication. Lubricating oil used for work on the bearing of these components needs to be maintained in conditions, especially temperature conditions, so a lubricating oil cooler is needed to cool the lubricant so that it can be reused. Plate Heat Exchanger design with a heat transfer capacity of 734 kW is made as a lubricating oil cooler with an oil flow rate of 60𝑚3/hour in geothermal power plants. By raising the analysis of the addition of gap between plates, which is one of the important factors in designing a PHE. This scientific work examines the effect of increasing plate distance on the area of total heat transfers and total pressure drops. The plate spacing in design calculation method is varied and other variables are assumed to be constant. Increasing the distance of the plate increases the cross-sectional area and equivalent diameter, and decreases the velocity of the fluid in the channel and the Reynold number. So that there is an increase in the area of heat transfer and a reduction in pressure drop. Keywords: Plate Heat Exchanger, plates gap, pressure drop.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Arya Wulung, S.T., M.T.

    Pembimbing 2: Ir. Teguh Sasono, M.T., Editor: Erlin Arvelina

Download...