Rancangan MED-TVC Tipe Backward Feed Untuk PLTU 315 MW
The Design of Backward Feed Type MED-TVC System for 315 MW Steam Power Plant
Tugas Akhir, 023 / 2017 / TPTLUndergraduate Theses from JBPTPPOLBAN / 2018-09-03 15:05:20
Oleh : Syaipul Ulum - 131724030 (ipululum46@gmail.com)
Dibuat : 2017-12-08, dengan 4 file
Keyword : PLTU, MED-TVC, Desalinasi, Evaporator, Performance Ratio
Subjek : Steam Power Plant, MED-TVC, Desalination, Evaporator, Performance Ratio
Multi-Effect Desalination dengan tambahan Thermal Vapor Compression (ejector) (MED-TVC) dengan tipe aliran backward feed merupakan sistem pemurnian air laut yang berfungsi untuk menghilangkan kandungan garam dari air laut (desalinasi) dengan metoda penguapan. Air hasil penguapan ini digunakan untuk memenuhi kebutuhan air umpan dan air servis pada sistem PLTU. Sebagai permulaan dari perancangan dilakukan simulasi sistem PLTU pada perangkat lunak Gate Cycle untuk mengetahui jumlah air yang dibutuhkan. Setelah didapatkan kebutuhan air, selanjutnya melakukan perancangan dengan menghitung kesetimbangan energi dan massa, penurunan temperatur, luas perpindahan panas, menghitung jumlah tube, dan menentukan penyesuaian untuk ejektor dan dimensi dari evaporator sesuai dengan literatur. MED-TVC yang telah dirancang akan menghasilkan air produk sebesar 20 [kg/s] atau 72 [m^3/jam] dengan jumlah tube setiap efek sebanyak 1.560 buah, panjang tube 5.000 [mm], diameter luar tube 50,8 [mm], dan tebal 0,71 [mm]. Penambahan TVC pada sistem MED akan meningkatkan nilai performance ratio sekitar 35% dan perubahan temperatur heating steam akan memengaruhi kinerja dari MED-TVC. Kata kunci: PLTU, MED-TVC, Desalinasi, Evaporator, Performance Ratio.
Deskripsi Alternatif :Multi-Effect Desalination with additional Thermal Vapor Compression (ejector) (MED-TVC) with backward feed flow type is a seawater purification system that serves to remove salt content from seawater (desalination) by evaporation method. This evaporated water is used to meet the needs of feed water and servicing water in the steam power plant system. As the beginning of the design, simulation of steam power plant system in the Gate Cycle software to know the amount of water needed. After obtaining water requirements, then do the design by calculating the equilibrium of energy and mass, decreasing temperature, heat transfer area, calculating the number of tubes, and determining the adjustment for the ejector and the dimensions of the evaporator according to the literature. The MED-TVC has been designed to produce a product water of 20 [kg/s] or 72 [m^3/jam] with the number of tubes of any effect is 1,560 pieces, tube length is 5,000 [mm], outer diameter of tube is 50.8 [mm], And thickness is 0.71 [mm]. The addition of TVC to the MED system will increase the performance ratio by 35% and the change in heating steam temperature will affect the performance of MED-TVC. Keywords: Steam Power Plant, MED-TVC, Desalination, Evaporator, Performance Ratio.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Drs. Maridjo, M.T.
Pembimbing 2: Dr. Ir. Sri Wuryanti, M.Si., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN TA - 131724030.pdf
(670958 bytes)
File : BAB 1 - 131724030.pdf
(103822 bytes)
File : BAB 2 - 131724030.pdf
(381522 bytes)
File : BAB 5 - 131724030.pdf
(116734 bytes)