Path: Top > Tugas Akhir - D3 > Jurusan Teknik Elektro > Program Studi Teknik Listrik > 2013

Simulator Losses Energi Non Teknis Pada APP 900VA (P3) dan Saluran Rumah (P4)

Simulator Energy Non-Technical Losses At APP 900VA (P3) and the Home Chanel (P4)

Tugas Akhir, 086 / 2013 / TLI
Undergraduate Theses from JBPTPPOLBAN / 2017-05-18 16:31:49
Oleh : Taruna Eki Wahyudi - 101321064 (tarunaekiw@yahoo.com)
Dibuat : 2017-05-18, dengan 4 file

Keyword : Losses energi listrik non teknis, Pelanggaran 3 dan Pelanggaran 4
Subjek : non-technical Losses electrical energy, and Breach 3 and Breach 4

Dalam proses pendistribusian energi listrik, PLN masih mengalami hilan genergi. Besarnya susut energi dari PLN berupa presentase global maka untuk dapat menekan angka susut energi lebih efektif yaitu dengan memisahkan susut antara teknis dengan non teknis. Terdapat beberapa modus-modus pelanggaran non teknis yang dilakukan oleh konsumen listrik dalam menikmati energi listrik yang diproduksi oleh PLN diantaranya yaitu pelanggaran yang dinamakan dengan pelanggaran P1, P2, P3 dan P4. Pelanggaran3 (P3) adalah pelanggaran yang mempengaruhi batas daya da npengukuran (APP). Contohnya jumper MCB dan jumper kWh. Pelanggaran4 (P4) adalah Pelanggaran yang dilakukan oleh pengguna listik yang tidak terdaftar di PLN (non konsumen). Contohnya: pencantolan pada saluran rumah. Dalam proyek akhir ini akan dibuat simulator losses energi non teknis pada APP 900VA (P3) dan pada Salura nRumah (P4). Simulator ini terdiri dari 1 kWH meter, 3 buah MCB, 9 beban lampu pijar, 5 buah saklar tunggal dan 4 buah stop kontak. Sistem kerja dari simulator ini adalah menunjukan pelanggaran-pelanggaran yang dilakuka noleh pelanggan listrik, dengan melihat pemakaian energi yang digunakan dari hasil pengujian pada simulator ini. Kata kunci: Losses energilistrik non teknis, Pelanggaran 3 dan Pelanggaran 4.

Deskripsi Alternatif :

In the process of distributing electricity, PLN still experiencing missing energy. The amount of energy losses in the form of a percentage of global PLN then to be able to reduce the number of losses the energy more effectively by separating shrinkage between the technical and non technical. There are several modes of non-technical violations committed by electricity consumers in enjoying the electric energy produced by PLN of them is called the violation offense P1, P2, P3 and P4. Violation 3 (P3) is a violation that affects the power limit and measurement (APP). Examples jumper and jumper MCB kWh. Violations 4 (P4) are violations committed by users who are not registered in electric PLN (non-consumer). For example: connect from home channel In this final project will be made non-technical energy losses simulator on APP 900VA (P3) and the Home Channel (P4). The simulator consists of 1 kWh meter, 3 pieces of MCB, incandescent lamp load 9, 5 and 4 single switch socket. Working system of this simulator is to show the violations committed by electricity customers, by looking at the energy consumption of the test results used in this simulator. Keywords: non-technical Losses electrical energy, and Breach 3 and Breach 4.

Beri Komentar ?#(1) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Drs. Dwi Asmono, M.Pd.

    Pembimbing 2: Ir. Hari Purnama, M.Eng., Editor: Erlin Arvelina

Download...