Path: Top > Tugas Akhir - D3 > Jurusan Teknik Refrigerasi dan Tata Udara > Program Studi Teknik Refrigerasi dan Tata Udara > 2013

Analisis Performansi Mini Freezer Akibat Pengaruh Refrigeran Sekunder dan Variasi Panjang Pipa Kapiler

Analysis Due to Mini Freezer performance Effect and variation of Secondary Refrigerant Piping length Capillary

Tugas Akhir, 007 / 2013 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2017-04-10 15:46:10
Oleh : Vitri Anggraeni Rosliadi - 101611064 (rosliadivitrianggraeni@gmail.com)
Dibuat : 2017-04-10, dengan 4 file

Keyword : freezer unit kecil, retrofitting, refrigeran sekunder, konsumsi energi
Subjek : mini freezer, retrofitting, secondary refrigerant, energy consumption

Penyimpanan produk dalam jangka waktu yang lama membutuhkan energi yang begitu banyak dan refrigeran primer yang harus dipertimbangkan keamananya, untuk memenuhi keperluan akan mesin freezer unit kecil yang dapat digunakan dengan catu daya terbatas, hemat energi dan ramah lingkungan maka penulis membuat tugas akhir dengan judul “Analisis Performansi Mini Freezer Akibat Pengaruh Refrigeran Sekunder dan Variasi Panjang Pipa Kapiler”. Dengan tujuan untuk membandingkan kinerja sistem pengaruh retrofitting, pengaruh rerfrigeran sekunder terhadap kinerja sistem, performansi sistem akibat variasi panjang pipa kapiler dan banyaknya penghematan energi. Metodologi yang digunakan yaitu dengan membuat prototipe mesin mini freezer yang dilengkapi refrigeran sekunder dengan konsentrasi 20% propylene glycol dan 80% air, selanjutnya dilakukan pengambilan data untuk menganalisa akibat retrofitting, pengaruh refrigeran sekunder dan pengaruh variasi panjang pipa kapiler. Kesimpulan yang didapat menunjukkan bahwa sistem refrigerasi mini freezer yang menggunakan R290 dengan panjang pipa kapiler standar dan dilengkapi dengan refrigeran sekunder adalah yang terbaik dengan nilai performansi (COP) sebesar 3,6; efisiensi sistem 86,199%, dan lamanya waktu mempertahankan temperatur kabin (cut-out) adalah 19,253 jam atau 1155,2 menit. Kata kunci: freezer unit kecil, retrofitting, refrigeran sekunder, konsumsi energi.

Deskripsi Alternatif :

Storage products in the long term requires so much energy and primary refrigerant that must be considered safety, to meet the need for machine freezer small unit that can be used with a limited power supply, energy saving and environmentally friendly, the authors make the final project titled "Analysis Due to Mini Freezer performance Effect and variation of Secondary Refrigerant Piping length Capillary ". With the aim to compare the effect of system performance retrofitting, secondary rerfrigeran influence on system performance, system performance due to variations in capillary length and number of energy savings. The methodology used is to create a mini-freezer prototype machine equipped with a secondary refrigerant concentration of 20% propylene glycol and 80% water, is then performed to analyze the data collection due to retrofitting, the influence of secondary refrigerant and the effect of variations in length of the capillary. The conclusion shows that the mini-freezer refrigeration systems that use R290 with standard capillary tube length and is equipped with a secondary refrigerant is the best with the value of performance (COP) of 3.6; 86.199% system efficiency, and the length of time maintaining cabin temperature (cut-out) is 19.253 hours or 1155.2 minutes. Guide word: mini freezer, retrofitting, secondary refrigerant, energy consumption.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Triaji Pangripto Pramudantoro, S.T., M.Eng.

    Pembimbing 2: A. P. Edi Sukamto, S.T., M.T., Editor: Erlin Arvelina

Download...