Evaluasi Konsumsi Energi Di PT. PDAM Tirta Raharja Melalui Audit Awal Pada Pompa Intake Dan Pompa Distribusi

Evaluation Of The Consumption Of Energy At PT. PDAM Tirta Raharja First Audit By Preparation Pump And Distribution Pump

Tugas Akhir, 002 / 2016 / TLI
Undergraduate Theses from JBPTPPOLBAN / 2017-08-04 15:16:05
Oleh : Winda Suci Rahayu – 131321031 (windasucirahayu@gmail.com)
Dibuat : 2017-08-04, dengan 4 file

Keyword : Intensitas Energi, Produksi, Konsumsi.
Subjek : Energy Intensity, Production, Consumption.

PT. PDAM Tirta Raharja adalah sebuah instansi yang memiliki peran untuk memberi pelayanan air bersih untuk masyarakat Kabupaten Bandung. Evaluasi konsumsi energi merupakan suatu cara dalam langkah untuk mengoptimalkan penggunaan konsumsi energinya tanpa harus mengurangi jumlah produksinya. Tujuan dari penelitian ini adalah untuk menghasilkan rekomendasi dengan menggunakan audit awal. Nilai rata – rata intensitas energi menunjukan 99,36 kWh/m3/bulan dan termasuk pada kategori effisien. Selain itu pula pengaruh produksi terhadap konsumsinya terjadi fluktuasi, ini didukung oleh CUSUM jika nilainya dibawah 0 maka nilai minimumnya adalah -18691,2 dan nilai maksimumnya adalah 1793,951 . Ini berarti bahwa nilai produksi terhadap konsumsinya kurang effisien. Dalam rangka meningkatkan kwalitas intensitas energinya dan menjadikan nilai produksi terhadap konsumsinya menjadi effisien, serta meningkatkan kwalitas intensitas energi dari effisien menjadi sangant effisien yaitu perlu di adakannya audit rinci. Kata Kunci : Intensitas Energi, Produksi, Konsumsi.

Deskripsi Alternatif :

PT. PDAM Tirta Raharja is an institution that has a role to provide a clean water service to the community of Bandung regency. Evaluation of energy consumption is a way to optimize the use of its energy consumption without having to reduce the amount of production. The purpose of this study is to make a recommendation to use the initial audit. the value average of energy intensity is 99.36 kWh /m3/month and includes to the efficient category. Moreover, the effect of production to consumption is a fluctuation, it is supported by CUSUM if the value is less than 0 then the minimum value is -18,691.2 and the maximum value is 1793.951. This means that the value of production on consumption is less efficient. In order to improve the quality of energy intensity and makes the value of production to consumption to be efficient. and improve the quality of efficient energy intensity becomes very efficient that needs to do a detailed audit. Keywords: Energy Intensity, Production, Consumption.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing : Heri Budi Utomo

    Pembimbing II : Supriyanto, ST.,MT
    , Editor: Muhammad Abdillah Islamy, S.Pd

Download...