Pada penelitian ini dilakukan pengkajian penggunaan bioetanol pada gensetET 1800L berkapasitas kecil terhadap tingkat kebisingan dengan menggunakan alat Sound Level Meter. Pengujian tingkat kebisingan dilakukandengan variasi jarak 0,1 meter, 0,3meter, 0,5meter, 1 meter, 1,5 meter dan 3 meter dari posisi knalpot generator set pada variasi beban resistif: beban nol, beban 1 (140 ohm) dan beban 2 (69,6 ohm), dan variasi beban lampu: 100, 200, 300, 400 dan 500 watt. Dari hasil pengujian diperoleh tingkat kebisingan genset yang paling halus, baik dengan beban resistif dan beban lampu adalah pada genset berbahan bakar gasohol 5%, dengan tingkat di bawah batas ambang yakni kurang dari 85 dB diperoleh pada jarak 1,5 dan 3 meter.Di samping itu pada genset dengan bahan bakar gasohol 5% diperoleh kinerja dan emisi gas buang (CO & HC)yang cukup baik dibandingkan bahan bakar yang lainnya, sehingga penggunaan gasohol pada genset ini direkomendasikan pada konsentrasi 5%. Kata kunci: bioetanol, gensetET 1800L, sound level meter, tingkat kebisingan
Deskripsi Alternatif :This research studies the use of ethanol in a small capacity generator 1800 LET the noise level by using a Sound Level Meter. Tests carried out with variations of the noise level within 0.1 meter, 0.3 meter, 0.5 meter, 1 meter, 1.5 meters and 3 meters from generator set exhaust position on resistive load variations: zero load, load 1 (140 ohm) and load 2 (69.6 ohms), and variations of light load: 100,200,300, 400 and 500 watts. From the test resuls obtained genset noise levels most refined, both with a resistive load and light load is on gasohol-fueled genset 5%, a level below the threshold that is less than 85dBis obtained at a distance of1.5 and 3 meters. In addition to the generator with fuel gasohol 5% found the performance and exhaust emissions(CO andH C) were pretty good compared to the fuels, so the use of gasoholin the genset is recommended at a concentration of 5%. Keywords: bioethanol, gensetET 1800L, sound level meter, noise impact
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Dra. Tina Mulya Gantina, MT., Editor: Erlin Arvelina
Download...
File : DAFTAR - 091711064.pdf
(649147 bytes)
File : BAB 1 - 091711064.pdf
(395436 bytes)
File : BAB 2 - 091711064.pdf
(463113 bytes)
File : BAB 5 - 091711064.pdf
(242754 bytes)