Pembuatan Sistem Pengendali Temperatur Pada Pemanas Air Surya Berbasis Mikrokontroler ATmega8
The Manufacture Of Temperature Control System On Solar Water Heater Based On The ATmega8 Microcontroller
Tugas Akhir, 055 / 2014 / TENUndergraduate Theses from JBPTPPOLBAN / 2018-04-20 10:38:15
Oleh : Yoseph Maulana - 111711032 (yosephmaulana07@gmail.com)
Dibuat : 2018-04-20, dengan 4 file
Keyword : Solar Water Heater, mikrokontroler atmega8, Bascom AVR, LM35
Subjek : Solar Water Heater, Microcontroller ATMega8, Bascom AVR, LM35
Air panas kini sudah banyak digunakan untuk keperluan sehari-hari salah satunya adalah untuk mandi di perumahan dan sudah menjadi barang yang lazim. Para pengguna biasanya menggunakan Solar Water Heater, karena cara kerja alat yang sederhana memanfaatkan pancaran dari matahari yang gratis. Sayangnya, kebanyakan produk dipasaran cara kerjanya masih manual yaitu untuk menghidupkan atau mematikan Solar Water Heater masih dilakukan konvensional. Tugas akhir ini menitikberatkan pada sistem kendali temperatur di Solar Water Heater, dimana temperatur air yang diinginkan pengguna dapat diset dan ditampilkan pada LCD M1632. Sistem pengendali ini menggunakan mikrokontroler ATMega8 sebagai pengendali utama dan input dari sensor temperatur LM35. Jenis program yang digunakan untuk menjalankan semua perintah yang diinginkan oleh mikrokontroler ATMega8 yaitu menggunakan bahasa basic pada perangkat lunak Bascom AYR. Sistem kendali temperatur yang telah dibuat kemudian diuji dengan beberapa set point yaitu saat 40 0C dan 50'0C, karena berdasarkan kesehatan temperatur terbaik air hangat yaitu 38-40 0C. Pengujian untuk set point 50 0C ditujukan sebagai pembanding dan untuk uji coba perubahan set point. Saat mencapai set point yang diinginkan pompa akan berhenti bekerja sesuai dari perintah yang sudah diprogram. Dan hasil pembacaan sensor temperatur akan ditampilkan pada LCD 16x2. Respon waktu tercepat untuk mencapai set point 40 0C yaitu 120 detik dengan rata-rata radiasi 659 W/m2 untuk kapasitas air yang digunakan sebanyak 1,2 liter. Sedangkan respon waktu tercepat pada set point 50 0C yaitu 240 detik dengan rata-rata radiasi 655,22 W/m2 untuk kapasitas air yang digunakan sebanyak 1,2 liter. Kata kunci: Solar Water Heater, mikrokontroler atmega8, Bascom AVR, LM35.
Deskripsi Alternatif :The hot water has been widely used for bathing purposes and has become a common item. Customers typically use a Solar Water Heater, because a simple system works by utilizing radiation from the sun for free. Unfortunately, solar water heater sold in the market mostly still works manually. So in this case the user also usually add more cold water to adjust the desired water temperature. The final project focused on temperature control system in Solar Water Heater, which the user desired water temperature can be set and displayed on the LCD M1632. The control system using a microcontroller ATMega8 as the main controller and the input of the LM35 temperature sensor. And the type of program for microcontroller ATMega8 that use basic language in Bascom AVR software. From the making of this control system the user isn't difficult to turn off or turn on Solar Water Heater, just to set the desired temperature of the Solar Water Heater will work automatically. Temperature control system has been created and then tested on a different set point 40 0C and 50 0C, the set point setting is based on the health article that the best warm water temperature for body is 38-40 0C. When it reaches the desired set point the pump will stop working based on pre- programmed commands. The results of the temperature sensor readings are displayed on a 16x2 LCD. The fastest response time to reach the set point at 40 0C is 120 seconds with an average radiation 659 W / m2 and the capacity of the water used is1.2 liter. While the fastest response time in the set point at 50 0C is 240 seconds with an average radiation 655.22 W / m2 and the capacity of the water used is 1.2 liter. Keywords: Solar Water Heater, Microcontroller ATMega8, Bascom AVR, LM35.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Siti Saodah, S.T., M.T.
Pembimbing 2: Sri Utami, S.ST., M.T., Editor: Erlin Arvelina
Download...
File : DAFTAR - 111711032.pdf
(549248 bytes)
File : BAB 1 - 111711032.pdf
(281927 bytes)
File : BAB 2 - 111711032.pdf
(593589 bytes)
File : BAB 5 - 111711032.pdf
(343104 bytes)