Path: Top > Tugas Akhir - D3 > Jurusan Teknik Refrigerasi dan Tata Udara > Program Studi Teknik Refrigerasi dan Tata Udara > 2016
Uji Performansi Sistem Pendingin Pada Miniatur Ice Skating Dengan Txv Dan Pipa Kapiler Sebagai Alat Ekspansi
Test of Performance Cooling System of Miniature Ice skating With the Use TXV And Capillary Tube As The Expansion Tool
Tugas Akhir, 029 / 2016 / RTUUndergraduate Theses from JBPTPPOLBAN / 2017-09-04 11:22:12
Oleh : Yuda Wardiana - 131611061 (yudawardiana@gmail.com)
Dibuat : 2017-09-04, dengan 4 file
Keyword : Ice Skating, TXV,Capillary Tube, COPa
Subjek : Ice Skating, TXV, Pipa Kapiler, COPa
Ice Skating merupakan salah satu pemanfaatan dari ilmu teknik refrigerasi, dengan pendinginan sistemnya dimanfaatkan untuk membekukan air pada kolam dengan dimensi tertentu yang akan digunakan untuk area olah raga seluncur es. Pada tugas akhir ini dilakukan analisis uji performansi pendinginan pada sistem miniatur ice skating. Miniatur ice skating yang akan digunakan merupakan sistem kompresi uap, dengan komponen utama sistem yaitu kompresor, kondenser, alat ekspansi dan evaporator. Dengan bak penampung air yang dibekukan berkapasitas 20 liter untuk temperatur pembekuan sampai -13ºC. Miniatur sistem ice skating direkayasa dengan menggunakan dua jenis alat ekspansi yakni TXV(Thermostatic Expansion Valve) dan pipa kapiler. Untuk pengambilan data dilakukan masing-masing pada saat sistem dioperasikan dengan TXV dan dengan pipa kapiler, hal itu untuk mengetahui variasi data performansi sistem. Dari hasil perhitungan, untuk miniatur ice skating dengan menggunakan TXV didapatkan nilai efek refrigerasi (qe)= 162,64 kJ/kg, kapasitas kondensasi (qc)= 208,86 kJ/kg, COPa= 3,53, dan efisiensi, sistem= 65 %. Sedangkan untuk miniatur ice skating yang menggunakan pipa kapiler didapatkan nilai efek refrigerasi (qe) = 171,12 kJ/kg, kapasitas kondensasi (qc) = 211,03 kJ/kg, COPa= 4,39 , efisiensi = 83,47%. Kata kunci : Ice Skating, TXV, Pipa Kapiler, COPa
Deskripsi Alternatif :Ice Skating is one of the system that utilized refrigeration engineering, cooling system utilized to freeze the water in the pond with certain dimensions to be used for ice skating sports area. In this final project to analysis of cooling system performance test miniature ice skating. Miniature ice skating will be used a vapor compression systems, the main components of the system: compressor, condenser, expansion device and evaporator. With a frozen water reservoir with a capacity of 20 liters for freezing temperatures up to -13ºC. Miniature ice skating engineered system using two expansion device types, that is TXV (Thermostatic Expansion Valve) and the capillary. For data retrieval is done respectively by the time the system is operated with TXV and the capillary tube, it is to determine performance data of the system. From the calculation, miniature ice skating using a TXV obtained values, that is refrigeration effect (qe) = 162.64 kJ / kg, condensation capacity (qc) = 208.86 kJ / kg, COPa = 3.53, and efficiency of system = 65%. As for the miniature ice skating that uses a capillary tube refrigeration effect values obtained (qe) = 171.12 kJ / kg, condensation capacity (qc) = 211.03 kJ / kg, COPa = 4.39, efficiency = 83.47%. Keywords: Ice Skating, TXV,Capillary Tube, COPa
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1 : Tandi Sutandi, SST., MT ; Pembimbing 2 : Triaji Pangripto Pramudantoro, ST., M.Eng, Editor: Muhammad Abdillah Islamy, S.Pd
Download...
File : KELENGKAPAN TA - 131611061.pdf
(592146 bytes)
File : BAB 1 - 131611061.pdf
(380458 bytes)
File : BAB 2 - 131611061.pdf
(865052 bytes)
File : BAB 5 - 131611061.pdf
(404143 bytes)