Evaluasi Efektivitas Penggunaan Resin pada Sistem Demineralizer Air Tangki Reaktor Triga 2000
Evaluation Of the Effectiveness of Resin Use in The Triga 2000 Reactor Tank Water Demineralizer System
Tugas Akhir, 001 / 2022 / TENUndergraduate Theses from JBPTPPOLBAN / 2024-11-29 10:06:25
Oleh : 191711002 - Adyuta Inastrian Maphalita (adyuta.inastrian.tken19@polban.ac.id)
Dibuat : 2024-11-29, dengan 4 file
Keyword : sistem demineralizer, efektivitas resin, konduktivitas
Subjek : demineralizer system, resin effectiveness, conductivity
Sistem demineralizer merupakan sistem yang berfungsi untuk merawat air tangki reaktor agar nilai konduktivitas tetap dibawah 3,5 µmhos untuk mencegah korosi pada komponen reaktor yang terpapar air, terutama elemen bahan bakar. Demineralizer melakukan fungsi ini dengan menghilangkan kotoran larut dari air menggunakan resin mixed bed. Resin yang digunakan merupakan resin khusus yang di desain untuk nuklir yaitu Amberlite IRN 150 H/OH Ion Exchange Resin. Menurut Laporan Analisis Keselamatan (LAK), resin harus diganti setelah 6 bulan pemakaian. Telah dilakukan penelitian pada saat penggantian resin setiap 6 bulan sekali dengan penggunaan kontinu 12 hari selama satu bulan. Rata-rata nilai konduktivitas air tangki reaktor berada pada 0,9-1,1 µmhos dengan catatan tidak ada penambahan air tangki reaktor di tengah siklus penggunaan resin selama 6 bulan. Analisis dilakukan dengan membandingkan nilai pH, konduktivitas, dan kadar mineral pada setiap siklus resin dari tahun 2020 hingga 2021.Hasil analisis menunjukkan resin mampu bekerja dengan baik dan efektivitas resin mencapai 77%-92%. Waktu penggunaan resin dalam satu siklus bervariasi tergantung pada aktivitas zat kotoran yang larut pada air tangki reaktor. Kata kunci: sistem demineralizer, efektivitas resin, konduktivitas.
Deskripsi Alternatif :The demineralizer system is a system that functions to treat reactor tank water so that the conductivity value remains below 3.5 µmhos to prevent corrosion of reactor components exposed to water, especially the fuel element. The demineralizer performs this function by removing soluble impurities from the water using a mixed bed resin. The resin used is a special resin designed for nuclear, namely Amberlite IRN 150 H/OH Ion Exchange Resin. According to the Safety Analysis Report (LAK), the resin should be replaced after 6 months of use. Research has been carried out when replacing resin every 6 months with continuous use of 12 days for one month. The average conductivity value of reactor tank water is at 0.9 â 1.1 µmhos with a note that there is no addition of reactor tank water in the middle of the 6-month resin usage cycle. The analysis was carried out by comparing the pH value, conductivity, and mineral content in each resin cycle from 2020 to 2021. The results showed that the resin was able to work well and the effectiveness of the resin reached 77% - 92%. The time of using the resin in one cycle varies depending on the activity of the impurities dissolved in the reactor tank water. Keywords: demineralizer system, resin effectiveness, conductivity.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Alvera Apridalianti M., S.T., M.T.
Pembimbing 2: Indriyani, S.T., M.T., Editor: Erlin Arvelina
Download...
File : KELENGKAPAN TA - 191711002.pdf
(938621 bytes)
File : BAB 1 - 191711002.pdf
(392667 bytes)
File : BAB 2 - 191711002.pdf
(1252136 bytes)
File : BAB 5 - 191711002.pdf
(368998 bytes)