Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Konversi Energi > Program Studi Teknik Konversi Energi > 2022

Eliminasi Harmonisa pada Uninteruptible Power Supply (UPS) On-Line Berbasis Simulasi

Elimination of Harmonics in a Simulation-based Uninterruptible Power Supply (UPS) On-Line

Tugas Akhir, 003 / 2022 / TEN
Undergraduate Theses from JBPTPPOLBAN / 2024-11-29 10:47:17
Oleh : 191711017 - Muhammad Hafiz Firdausi (firdausihafiz@gmail.com)
Dibuat : 2024-11-29, dengan 4 file

Keyword : UPS, Uninteruptible Power Supply, mode operasi normal, mode operasi stored energi, eliminasi harmonisa, buck regulator, penyearah, PWM inverter
Subjek : UPS, Uninteruptible Power Supply, normal operation mode, stored energy operation mode, harmonic elimination, buck regulator, rectifier, PWM inverter

Tugas akhir ini membahas tentang eliminasi harmonisa pada uninterruptible power supply (UPS) berbasis simulasi. Sistem UPS pada umumnya terdiri dari PWM inverter, penyearah tiga fasa gelombang penuh, charger, dan baterai. Komponen tersebut terintegrasi satu sama lain untuk menghasilkan tegangan output satu fasa yang sesuai dengan kebutuhan beban. UPS berfungsi untuk menyimpan persediaan daya listrik sementara ketika tidak terdapat suplai daya listrik dari sumber ke peralatan elektronik/beban. Secara umum UPS digunakan untuk backup aliran listrik ketika terjadi pemadaman listri. Selain itu UPS juga berfungsi untuk menstabilkan tegangan listrik dan mencegah kerusakan elektronik. UPS dapat beroperasi pada operasi normal dimana daya dialirkan dari sumber ke beban, namun UPS juga dapat beroperasi pada mode operasi darurat ketika terdapat gangguan daya listrik maka baterai mengambil alih fungsi suplai untuk memasok daya ke beban. UPS pada umumnya masih memiliki nilai harmonisa yang tinggi, untuk mengurangi nilai harmonisa yang tinggi. Dilakukan eliminasi harmonisa dengan mengganti rancangan UPS yang pada umumnya memiliki nilai harmonisa yang tinggi dengan rancangan yang memiliki nilai harmonisa lebih rendah. UPS hasil rancangan akan didesain dengan mengganti komponen utama dengan inverter multilevel untuk mengeliminasi harmonisa pada sisi output/beban, penyearah 12 pulsa dan buck regulator untuk mengeliminasi harmonisa pada sisi input/sumber. Hasil perancangan menunjukan bahwa UPS hasil rancangan bekerja dengan baik sesuai dengan tujuan untuk mengurangi nilai harmonisa yang terjadi pada UPS tanpa mengurangi fungsi dari UPS itu sendiri.

Deskripsi Alternatif :

This project discusses the elimination of harmonics in a simulation-based uninterruptible power supply (UPS). UPS is a system generally consists of PWM inverter, full-wave three-phase rectifier, charger, and battery. These components are integrated with each other to produce a single-phase output voltage that suits the load requirements. UPS serves to store a temporary supply of electrical power when there is no supply of electrical power from the source to the electronic equipment/load. In general, UPS is used to backup electricity in the event of a power outage. In addition, the UPS also functions to stabilize the mains voltage and prevent electronic damage. The UPS can operate in normal operation where power is supplied from the source to the load, but the UPS can also operate in emergency operating mode when there is a power failure so the battery takes over the supply function to supply power to the load. UPS in general still has a high harmonic value, to reduce the high harmonic value. Harmonics are eliminated by replacing the UPS design which generally has a high harmonic value with a design that has a lower harmonic value. The UPS design will be designed by replacing the main components with a multilevel inverter to eliminate harmonics on the output/load side, a 12 pulse rectifier and a buck regulator to eliminate harmonics on the input/source side. The design results show that the designed UPS works well in accordance with the aim of reducing the harmonic values that occur in the UPS without reducing the function of the UPS itself.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Dr. I Made Wiwit Kastawan, M.T.

    Pembimbing 2: Ir. Achmad Mudawari, M.T., Editor: Erlin Arvelina

Download...