Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Refrigerasi & Tata Udara > Program Studi Teknik Pendingin & Tata Udara > 2024

Rancang Bangun Alat Penetas Telur Dengan Memanfaatkan Panas Buang Dari Kondenser AC Split

Design of Egg Hatching Tool Using Exhaust Heat From Split AC Condenser

Tugas Akhir, 004 / 2024 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2024-11-28 15:24:44
Oleh : 211611006 - Brilliant Ardan Nugraha (brilliant.ardan.tptu21@polban.ac.id)
Dibuat : 2024-11-28, dengan 4 file

Keyword : Rerfrigerasi, Tata udara, AC Split, Kondenser
Subjek : Refrigeration, Air Conditioning, AC Split, Condenser

Sistem refrigerasi atau tata udara merupakan sistem dengan prinsip dasar pertukaran kalor antara mesin pendingin dan ruangan atau produk. Dengan melihat prinsip dasar dari sistem refrigerasi atau tata udara, mesin pendingin memiliki dua sisi temperatur yaitu sisi temperatur rendah (evaporator) dan sisi temperatur tinggi (kondenser). Mesin pendingin ruangan seperti AC Split umumnya hanya kita gunakan untuk mendapat suplai udara dingin dari indoor unit tanpa memanfaatkan udara panas yang dibuang di kondenser. Tujuan dari penelitian rancang bangun ini adalah agar panas buang dari kondenser juga bisa kita manfaatkan selain dari sisi pendinginan AC Split. Panas buang dari kondenser akan dimanfaatkan sebagai suplai panas untuk pengeraman penetasan telur dan akan dilihat dampaknya terhadap kinerja mesin AC Split tersebut. Metoda yang digunakan adalah dengan memasang saluran udara dari keluaran udara panas outdoor unit menuju lingkungan dan membuat jalur untuk udara panas menuju inkubator serta membuat pintu yang otomatis menutup suplai panas ke inkubator saat temperatur inkubator telah tercapai. AC yang digunakan yaitu AC Split DAIKIN 2 hp, beban pemanasan yang dibutuhkan inkubator adalah 29,7 Watt. Dari hasil penelitian rancang bangun ini 4 dari 12 telur dapat menetas lalu didapat performansi sistem setelah dimanfaatkan panas buang kondensernya, COPaktual 5,35 dan COPCarnot 7,55 dengan nilai efisiensi sistem sebesar 69%.

Deskripsi Alternatif :

The refrigeration or air conditioning system is a system with the basic principle of heat exchange between the cooling machine and the room or product. By looking at the basic principles of a refrigeration or air conditioning system, a cooling machine has two temperature sides, namely a low temperature side (evaporator) and a high temperature side (condenser). We generally only use air conditioning machines such as AC Split to get a supply of cold air from the indoor unit without utilizing the hot air that is discharged in the condenser. The aim of this design research is so that we can also utilize the exhaust heat from the condenser apart from the cooling side of the AC Split. The exhaust heat from the condenser will be used as a heat supply for incubation and hatching of eggs. The method used is to install an air duct from the hot air output of the outdoor unit to the environment and create a path for the hot air to the incubator and create a door that automatically closes the heat supply to the incubator when the incubator temperature has been reached. The AC used is a DAIKIN 2 PK split AC, the heating load required for the incubator is 29.7 Watts. From the results of this design research, 4 out of 12 eggs were able to hatch and then the system performance was obtained after using the condenser waste heat, COP actual 5.35 and COP Carnot 7.55 with a system efficiency value of 69%.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Triaji Pangripto Pramudantoro, S.T., M.Eng.

    Pembimbing 2: Luga Martin Simbolon, S.T., M.Sc., Ph.D., Editor: Erlin Arvelina

Download...