Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Refrigerasi & Tata Udara > Program Studi Teknik Pendingin & Tata Udara > 2024

Kaji Eksperimental Pengaruh Variasi Panjang Pipa Kapiler terhadap Kinerja AC Split dengan Variasi Massa Refrigeran Dimethyl Ether (DME)

Experimental Study of The Effect of Capillary Pipe Length Variation on Split AC Performance with Dimethyl Ether (DME) Refrigerant Mass Variation

Tugas Akhir, 005 / 2024 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2024-11-28 15:27:49
Oleh : 211611007 - Bunga Putri Shaumi (bunga.putri.tptu21@polban.ac.id)
Dibuat : 2024-11-28, dengan 4 file

Keyword : AC split, pipa kapiler, dimethyl ether, COP, konsumsi energi listrik
Subjek : Split air conditioner, capillary pipe, dimethyl ether, COP, electrical energy consumption

Pemanasan global merupakan ancaman yang saat ini telah hadir di hadapan kita. Berbagai cara telah dikembangkan untuk menciptakan perbaikan pada alat pengkondisian udara, seperti pemilihan refrigeran ramah lingkungan. Oleh karena itu, perlu ditemukan desain spesifik yang sesuai dengan refrigeran pengganti yang lebih ramah lingkungan salah satunya dapat dilakukan dengan memodifikasi panjang pipa kapiler sebagai alat ekspansi, dikarenakan pipa kapiler memiliki dampak yang cukup besar terhadap tinggi rendahnya temperatur yang didapat di dalam evaporator. Tujuan dari penelitian ini untuk mengevaluasi dampak dari variasi panjang pipa kapiler terhadap kinerja AC split dengan variasi massa refrigeran dimethyl ether (DME). Metode penelitian berupa eksperimen menggunakan AC split Daikin 1 PK dengan variasi panjang pipa kapiler 1 m; 1,1 m dan variasi pengisian massa DME 30% (132 gram); 50% (220 gram). Hasil penelitian menunjukkan bahwa penambahan panjang pipa kapiler dan penambahan massa refrigeran mempengaruhi kinerja sistem. Nilai COP pada variasi panjang pipa kapiler 1 m dengan variasi massa DME 30% dan 50% berturut-turut, yaitu 3,30 dan 5,13. Adapun hasil COP untuk variasi panjang pipa kapiler 1,1 m dengan variasi massa DME 30% dan 50% berturut-turut, yaitu 3,10 dan 5,06. Konsumsi energi listrik pada pengisian 30% DME dengan panjang pipa kapiler 1 m dan 1,1 m mendapatkan 0,64 kWh dan pada pengisian 50% DME dengan panjang pipa kapiler 1 m dan 1,1 m mendapatkan 0,80 kWh. Penelitian tugas akhir ini memberikan kontribusi dalam upaya mengurangi dampak lingkungan dari sistem pendinginan sejalan dengan kebutuhan akan solusi ramah lingkungan dalam menghadapi perubahan iklim global. Kata kunci: AC split, pipa kapiler, dimethyl ether, COP, konsumsi energi listrik.

Deskripsi Alternatif :

Global warming is a threat that is already upon us. Various ways have been developed to create improvements in air conditioning equipment, such as the selection of environmentally friendly refrigerants. Therefore, it is necessary to find a specific design that is in accordance with a more environmentally friendly replacement refrigerant, one of which can be done by modifying the length of the capillary pipe as an expansion device, because the capillary pipe has a considerable impact on the high and low temperatures obtained in the evaporator. The purpose of this study is to evaluate the impact of capillary pipe length variations on the performance of split air conditioners with variations in dimethyl ether (DME) refrigerant mass. The research method is an experiment using a 1 PK Daikin split air conditioner with a capillary pipe length variation of 1 m; 1.1 m and a DME mass charging variation of 30% (132 grams); 50% (220 grams). The results show that the addition of capillary pipe length and the addition of refrigerant mass affect system performance. The COP value for the capillary pipe length variation of 1 m with 30% and 50% DME mass variation is 3.30 and 5.13, respectively. The COP results for the 1.1 m capillary pipe length variation with 30% and 50% DME mass variations are 3.10 and 5.06, respectively. Electrical energy consumption at 30% DME filling with capillary pipe lengths of 1 m and 1.1 m gets 0.64 kWh and at 50% DME filling with capillary pipe lengths of 1 m and 1.1 m gets 0.80 kWh. This final project research contributes to efforts to reduce the environmental impact of the cooling system in line with the need for environmentally friendly solutions in the face of global climate change. Keywords: Split air conditioner, capillary pipe, dimethyl ether, COP, electrical energy consumption.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Prof. Dr. Ir. Andriyanto Setyawan, M.T.

    Pembimbing 2: Annisa Syafitri Kurniasetiawati, M.Sc., Editor: Erlin Arvelina

Download...