Analisis Struktur Atas pada Gedung Aula Asrama Haji Indramayu

Analysis of Upper Structure on Hall Building of Hajj Hostel Indramayu

Tugas Akhir, 016 / 2021 / KGE
Undergraduate Theses from JBPTPPOLBAN / 2022-06-13 09:56:44
Oleh : Aditiya Ghiyat Mustafa - 181111033 & Sugiono Angga Putra - 181111061 (aditiya.ghiyat.tkgd18@polban.ac.id & Sugionoanggaputra1@gmail.com )
Dibuat : 2022-06-13, dengan 4 file

Keyword : Earthquake Resistance Design, Reinforced Concrete, Strong Column Weak Beam
Subjek : Analisis Struktur Atas, Beton Bertulang, Strong Column Weak Beam

Gedung Aula Asrama Haji ini dalam proses pembangunannya masih menggunakan SNI lama yaitu SNI 1726-2012 mengenai tata cara perencanaan ketahanan gempa untuk struktur bangunan gedung dan nongedung dan SNI 2847-2013 mengenai persyaratan beton struktural untuk gedung. Hal ini menjadi sorotan di mana untuk sekarang sudah ada SNI yang lebih terbarukan yaitu SNI 1726-2019 dan SNI 2847-2019. Pembaharuan SNI ini terjadi dikarenakan dirasa sudah tidak relevannya aturan yang sudah dibuat dengan terjadinya gempa-gempa besar di Indonesia setelah tahun 2012. Proses analisis ini dilakukan dengan acuan standar SNI 1726-2019, SNI 2847-2019 dan SNI 1727-2020. Namun dalam analisis ini tidak semua persyaratan ditinjau, hanya sebagian saja seperti kombinasi beban, pembebanan pada SNI 1727-2020, penentuan bangunan gedung dan kekakuan tingkat pada SNI 1726-2019 dan analisis lentur, geser balok, lentur dan aksial, bergoyang atau tidak, dan geser kolom saja pada SNI 2847:2019. Elemen yang ditinjau pun tidak semuanya, untuk kolom hanya lantai 1 dan balok hanya titik tertentu, namun dalam pemodelan dengan software ETABS versi 2016, pemodelan dilakukan seluruh bagian, kecuali tangga, gedung bagian atas dan atap portal baja, yang bebannya dihitung sendiri lalu diinputkan manual ke model utama.Dari analisis ini dapat diambil kesimpulan bahwa untuk bagian yang ditinjau, untuk kekakuan tingkat sudah memenuhi , balok 7 dari 9 elemen tidak memenuhi persyaratan lentur sedangkan gesernya memenuhi, 6 dari 11 elemen kolom tidak memenuhi lentur dan aksial kolom, sedangkan gesernya memenuhi dan strong column weak beam dari 69 titik joint, 18 tidak memenuhi.

Deskripsi Alternatif :

Gedung Aula Asrama Haji is still under construction and using the old SNI that is SNI 1726-2012 about procedures for earthquake resistance design for building structures and SNI 2847-2013 about structural concrete requirements for buildings. This is a highlight because now there are more recent SNI, namely SNI 1726-2019 and SNI 2847-2019. This SNI renewal because the latest SNI was irrelevant and a lot of major earthquakes in Indonesia after 2012. This analysis process is referring to the standards of SNI 1726-2019, SNI 2847-2019 and SNI 1727-2020. However, in this case is not all needed to be reviewed, only part of it such as the combination of loads in SNI 1727-2020, making buildings and stiffness levels in SNI 1726-2019 and only bending analysis, beam shear, bending and axial, swaying or not, and column shear on SNI 2847:2019. Not all of the elements that are reviewed for columns, only on the 1st floor and certain point beams. But , the modeling is carried out in all parts, except for the stairs, the upper building and the steel portal of roof, which the load is calculated by manual and then inputted manual to the main model. From this analysis, it can be concluded that for the section being reviewed, for the stiffness of the story has already in accordance with the the requirements. As many as 7 of 9 beam elements are not in accordance with the flexural requirements even though the beams fulfill the shear requirement. A total of 6 out of 11 column elements are not in accordance with the combined flexural and axial column requirements, even though columns are according to shear requirements. Only 18 out of 69 columns reviewed are not in accordance with the strong column weak beam requirements.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id