Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Refrigerasi & Tata Udara > Program Studi Teknik Pendingin & Tata Udara > 2020
Analisis Efisiensi Cooling Tower Unit 3 pada Tahun 2017 di PT. Indonesia Power UPJP Kamojang
The Analysis of The 3rd Unit Cooling Tower Efficiency in 2017 at PT. Indonesia Power UPJP Kamojang
Tugas Akhir, 005 / 2020 / RTUUndergraduate Theses from JBPTPPOLBAN / 2021-11-30 09:44:04
By : Aulia Rizqaturrahmi Bone - 171611004 (aulia.rizqaturrahmi.tptu17@polban.ac.id)
Created : 2021-11-30, with 4 files
Keyword : cooling tower, range, approach, efficiency.
Subject : cooling tower, range, approach, efisiensi.
Perkembangan industri yang bergerak maju dengan pesat akan menuntut penyediaan energi yang cukup besar pula. Pembangkit tenaga listrik, merupakan salah satu penyedia yang memiliki kontribusi sangat penting di antara penunjangpenunjang energi lainnya. Salah satu jenis pembangkit listrik adalah Pembangkit Listrik Tenaga Panas Bumi (PLTP) yang memanfaatkan uap panas yang terkandung di dalam bumi untuk menggerakkan turbin dan generator. Cooling tower diperlukan di industri pembangkit listrik tenaga panas bumi seperti PT. Indonesia Power UPJP Kamojang yang menggunakan cooling tower untuk mendinginkan sistem pendingin utama maupun sekunder. Untuk mengetahui performansi efisiensi yang dimiliki cooling tower, maka diperlukan pengukuran efisiensi. Tugas akhir ini mengevaluasi efisiensi cooling tower pada tahun 2017. Dengan menggunakan data yang diamati pada bulan Januari dan Juni 2017. Pengukuran efisiensi ini dilakukan dengan menggunakan nilai range dan approach. Dengan hasil bahwa cooling tower lebih efisien pada saat musim hujan yaitu di bulan Januari dengan rata-rata nilai range sebesar 19,07â°C, approach 8,6â°C, dan efisiensi mencapai 68,8%.
Description Alternative :The industrial development which is moving forward rapidly will demand a large energy supply as well. The power plant is one of the providers that have a very important contribution among other energy supports. One of type power plant is Geothermal Power Plant (GPP) which uses hot steam contained in the earth to moves the turbine and generator. Cooling towers is needed in the geothermal power plant industry, such as PT. Indonesia Power UPJP Kamojang which uses a cooling tower to cool the primary and secondary cooling systems. To determine the effective performance of a cooling tower, it is necessary to measure it is effectiveness. This final project evaluates the efficiency of cooling towers in 2017. By using data taken in January and June 2017. Measurement of effectiveness is carried out using range and approach values. With the result that the cooling tower is more efficient during the rainy season, which is in January with an average range value is 19.07â°C, an approach is 8.6â°C, and efficiency reaching 68.8%.
Property | Value |
---|---|
Publisher ID | JBPTPPOLBAN |
Organization | |
Contact Name | Erlin Arvelina |
Address | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
City | Bandung |
Region | Jawa Barat |
Country | Indonesia |
Phone | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
Administrator E-mail | erlin.arvelina@polban.ac.id |
CKO E-mail | erlin.arvelina@polban.ac.id |