Modul Praktikum Perawatan dan Perbaikan Kendali Tekanan Menggunakan Kontrol PID

Maintenance and Repair Module Controlling Pressure Using PID Control

Tugas Akhir, 026 / 2015 / TEL
Undergraduate Theses from JBPTPPOLBAN / 2018-07-17 08:43:12
Oleh : Ayu Budiarti ( ayubudiarti95@gmail.com)
Dibuat : 2018-07-16, dengan 4 file

Keyword : Perawatan dan Perbaikan, PID, Tekanan, Pressure Gauge, Titik Pengamatan, Saklar Simulasi Kerusakan.
Subjek : Maintenance and Repair, PID Controller, Pressure, Pressure Gauge, Observation Point, Failure Simulation.

Modul Praktikum Perawatan dan Perbaikan Kendali Tekanan Menggunakan Kontrol PID. Proyek Akhir: Program D3 Teknik Elektronika. Politeknik Negeri Bandung. 2015 Modul praktikum perawatan dan perbaikan kendali tekanan ini dibuat untuk memenuhi kelengkapan modul praktikum mata kuliah MR (Maintenance and Repair). Modul ini menggunakan PID sebagai pengendali dan Pressure Gauge Transmitter KH50 sebagai pendeteksi tekanan. Dalam modul ini terdapat plant berupa tangki tertutup yang dilengkapi heater untuk memanaskan air sampai mencapai tekanan tertentu, dengan gangguan berupa katup (valve). Titik Pengamatan dibuat sebagai titik untuk melakukan pengukuran pada saat kondisi normal dan dilengkapi saklar untuk digunakan saat simulasi kerusakan dilakukan. PID digunakan untuk mengurangi error sehingga tekanan yang terbaca lebih presisi. Jika sistem dberi gangguan maka PID akan menjaga tekanan pada plant agar tetap konstan, dengan cara mengatur penyalaan heater. Hasil pengujian menunjukkan bahwa alat ini dapat mendeteksi tekanan dengan baik pada range 17.82 kPa s/d 76.92 kPa. Kata Kunci: Perawatan dan Perbaikan, PID, Tekanan, Pressure Gauge, Titik Pengamatan, Saklar Simulasi Kerusakan.

Deskripsi Alternatif :

Maintenance and Repair Module Controlling Pressure Using PID Control. Final Project: D3 Major in Electrical Engineering. State Polytechnic of Bandung. 2015 This final project is made to complete the experimental needs in MR (Maintenance and Repair) laboratory. This module is using PID as controller, and Pressure Gauge Transmitter KH50 as pressure sensor. There is a plant consists of a closed tank with a heater to heat the water until it reaches a certain pressure, and also a valve as distrubance. The observation point (TP) is a point to perform measurements during normal conditions and include a switch to be used when doing the failure simulation. PID is used to reduce the error, so this module can measure the pressure more precisely. If interference occurs then the pressure on the plant will remain constant, by controlling the heater. The test result showed that this module works well in the 17.82 kPa to 76.92 kPa range. Keywords: Maintenance and Repair, PID Controller, Pressure, Pressure Gauge, Observation Point, Failure Simulation.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Trisno Yuwono Putro, S.T., M.Eng.



    Pembimbing 2: Ir. Suheri Bakar, Editor: Erlin Arvelina

Download...