Sumber panas bumi dengan temperatur dan tekanan uap yang rendah tidak bisa dimanfaaatkan sebagai pembangkit listrik sehingga terbuang menjadi waste energi. Untuk memanfaatkan energi yang terbuang tersebut telah dilakukan perancangan pembangkit listrik Siklus Rankine organik dengan menggunakan R-134a sebagai fluida kerja dan memanfaatkan brine water pada Pembangkit Listrik Tenaga Panas Bumi sebagai fluida pemanas. Brine water yang digunakan memiliki temperatur sebesar 130oC dan tekanan 11 bar. Daya listrik yang dihasilkan oleh siklus Rankine organik ini adalah 100 kW dengan simulasi yang dilakukan pada perangkat lunak Aspen HYSYS V.88. Penulis telah merancang kondensor sebagai komponen utama pada siklus rankine organik ini. Fungsi dari kondensor ini adalah mengubah fasa fluida kerja dari fasa uap menjadi cair. Kondensor yang dirancang merupakan penukar panas tipe shell and tube (a two pass tube, baffled single pass shell) dengan head load 7522470 Btu/hr, serta OD 9 bwg (1 inch OD, 0,148 inc thick). Dari hasil perhitungan perancangan didapat panjang tube per pass sebesar 28 ft (8,5 m), diameter shell 33 in (0,83 m), jarak pitch 1,25 in (0,031 m) dan perpindahan secara keseluruhan 58,933 Btu/h ft oF. Kata kunci: siklus Rankine organik, brine water, alat penukar kalor, kondensor, R-134a.

Deskripsi Alternatif :

Geothermal sources with low temperature and vapor pressure can't be used as a power plant so that they are wasted into energy waste. To utilize the wasted energy has been done the design of the organic Rankine Cycle power plant by using R-134a as a working fluid and utilizing brine water in the Geothermal Power Plant as a heating fluid. Brine water used has a temperature of 130oC and a pressure of 11 bar. The electrical power generated by this organic Rankine cycle is 100 kW with simulations carried out on the Aspen HYSYS V.88 software. The author has designed condensers as a major component of this organic rankine cycle. The function of this condenser is to change the working fluid phase from the vapor phase to liquid. The designed condenser is a shell and tube (a two pass tube, baffled single pass shell) heat exchanger with a 7522470 Btu / hr head load, as well as a 9 bw OD (1 inch OD, 0.148 inc thick). From the design calculation results obtained tube length per pass is 28 ft (8.5 m), shell diameter 33 in (0.83 m), pitch distance 1.25 in (0.031 m) and overall displacement 58.933 Btu /hftoF . Keywords: organic Rankine cycle, brine water, heat exchanger, condenser, R-134a.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ika Yuliyani, S.T., M.T.

    Pembimbing 2: Dr. Ir. Sri Wuryanti, M.Si., Editor: Erlin Arvelina

Download...