Semakin berkembangnya teknologi elektronika maka beban-beban listrikpun semakin berkembang, semula beban listrik bersifat linier, akibat perkembangan teknologi eleektonika muncul beban listrik yang bersifat non linier. Beban non-linear yang terpasang pada suatu sistem tenaga listriksatu fasa seperti komputer, Air conditioner, TV, Lampu Hemat Energi dll dapat menghasilkan distorsi harmonisa arus maupun tegangan. Dengan semakin besarnya kandungan harmonisa pada suatu sistem maka kualitas daya yang dihasilkan pun akan semakin memburuk. Penggunaan filter harmonisa dalam sistem tenaga kelistrikan telah terbukti mampu meredam distorsi harmonisa tegangan maupun arus yang ditimbulkan oleh beban non-linear. Filter aktif merupakan salah satu solusi dari permasalan terhadap gangguan harmonisa. Penelitian ini bertujuan melakukan kajian unjuk kerja filter aktif. untuk mengkompensasi arus harmonisa yang dapat memperbaiki kualitas daya pada rumah tinggal. Dari hasil pembahasn dipeoleh bahwa pada beban listrik rumah inggal memiliki komponen harmonisa yang sangat tnggi, yaitu Total Harmonics Distorsion arus, THDI, dapat mencapai 183%. Dengan memasang filterakif secara parallel dengan beban nili THDI dapat direduksi sampai dengan 9,5% Kata kunci: Harmonisa, beban non-linear, filter aktif, Rumah tinggal.
Deskripsi Alternatif :The redevelopment of electronics technology so electrical loads keep growing. Originally electrical loads is liner, as a result of electronics technology development appeared an electrical loads that is non liner. Non-linear loads installed in a single phase power system such as computers, air conditioners, TVs, Energy saving lamps. can produce current or voltage harmonic distortion. With the greater harmonic content in a system, the quality of the power produced will worsen. The use of harmonic filters in electrical power systems has been proven to be able to reduce voltage and current harmonic distortions caused by non-linear loads. The active filters is one solution to the problem of harmonic interference. This research aims to conduct a study to show off active filter to compensate for current harmonic that can improve power quality work on in residential installations.As a result obtained that an electrical loads in residential house having harmonics components very high, which is The Current Total Harmonic Distortion can reach 183%. By installing an active filter in parallel with the non linear loads, THDI could be reduced up to 9,5%. Keywords: Harmonics, non-linear load, active filter, Residential loads.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- , Editor: Erlin Arvelina
Download...