Keyword : Pengering, Precooling Condenser, dan pembuangan kalor
Penelitian ini bertujuan untuk menangani kapasitas pembuangan panas/kalor kondenser pada dehumidifier mekanik yang besar dan mengetahui performansi sistem dehumidifier mekanik dari sisi refrigeran dengan menggunakan precooling kondenser. Dehumidifier mekanik yang digunakan merupakan modifikasi dari Ac Window merk Uchida type MP-W5MZ kapasitas kompresor ½ pk, kapasitas pendinginan 5000 btu/h menjadi sistem dehumidifier mekanik menggunakan dua kondenser dengan kapasitas (preecoling) ½ kali dari condenser yang utama (primary). Dari hasil analisis, besarnya persentase pelepasan kalor di kondenser dengan penyerapan panas di evaporator pada dehumidifier dengan menggunakan dua condenser sebesar 104,8% berarti kapasitas kalor yang dibuang di sistem 4,8% lebih besar dari pada kalor yang diserap di sistem. Efisiensi sistem pada sistem dehumidifier yang menggunakan dua kondenser dengan data pada menit ke 100 sebesar 69%. Besarnya kapasitas pelepasan kalor di kondenser utama sebesar 1,53 kW, precooling condenser sebesar 0,18 kW. Besarnya kapasitas pendinginan di evaporator sebesar 1,46 kW, rasio kompresi sebesar 2,53, COPactual sebesar 5,76, COPcarnot sebesar 8,25.
Deskripsi Alternatif :The study aims to handle the heat dissipation capacity condenser of a large mechanical dehumidifier and determine the performance of the mechanical dehumidifier system from the refrigerant side by using a precooling condenser. The mechanical dehumidifier used is a modification of the AC Window brand Uchida type MP-W5MZ compressor capacity ½ PK, cooling capacity 5000 btu/h into a mechanical dehumidifier system use two condensers with a capacity (precooling) ½ times the main condenser (primary). From the result of the analysis, the large percentage of heat release in the condenser by absorbing heat in the evaporator on the dehumidifier by using two condensers at 104,8% means the capacity discharged in the system is 4,8% greater than the heat absorbed in the system. The efficiency of the system on a dehumidifier system that uses two condensers with data at minute 100 is 69%. The amount of heat release capacity in the main condenser is 1,53 kW, precooling condenser is 0,18 kW. The amount of cooling capacity in the evaporator is 1,46 kW, compression ratio is 2,53, COPactual is 5,76 and COPcarnot is 8,25.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- , Editor: Erlin Arvelina
Download...