Analisis Intensitas Penerangan di Lantai 1 Gedung Akuntansi Berbasis Perangkat Lunak Dialux 4

Lighting Intensity Analysis on The 1st Floor of Accounting Building Based on Dialux 4 Software

Tugas Akhir, 049 / 2021 / TLI
Undergraduate Theses from JBPTPPOLBAN / 2023-03-13 10:09:11
Oleh : Muhamad Ibnu Arrobi - 181321050 (muhamad.ibnu.tlis18@polban.ac.id)
Dibuat : 2023-03-13, dengan 4 file

Keyword : Analysis, Lighting intensity, Dialux 4
Subjek : Analisis, Intensitas penerangan, Dialux 4

Gedung Akuntansi merupakan tempat berkegiatan bagi civitas akademika dari Politeknik Negeri Bandung. Pada Gedung Akuntansi tentunya tidak terlepas dari penerangan untuk membantu aktivitas sehingga menciptakan suasana yang nyaman. Seiring berjalannya waktu Gedung Akuntansi banyak mengalami perubahan seperti penambahan dan perubahan fungsi ruangan tetapi tidak disertai perubahan lampu. Oleh karena itu harus dilakukan analisis intensitas penerangan di Lantai 1 Gedung Akuntansi. Tujuan dibuatnya tugas akhir ini adalah mengetahui intensitas penerangan yang terjadi pada Lantai 1 Gedung Akuntansi dan perbandingan dengan standar aturan yang berlaku. Tahapan proses yang dilakukan dalam analisisa ini menghitung, mengukur intensitas penerangan dan melakukan simulasi dengan menggunakan perangkat lunak Dialux 4. Hasil intensitas penerangan pada lantai 1 berdasarkan rekomendasi SNI 6197:2011. Dari pengukuran yang memenuhi standar diantaranya Kelas tipe D, Gudang dan Koridor tipe B. Dari perhitungan yang memenuhi standar yaitu Gudang. Dari Simulasi Dialux 4 siang hari yang memenuhi standar diantaranya Kelas tipe D, Kelas tipe E, Gudang dan Koridor tipe B. Hasil dari simulasi Dialux 4 malam hari yang memenuhi standar diantaranya gudang dan Koridor tipe E. Dari hasil yang didapat berbeda dikarenakan terdapat faktor yang berpengaruh pada setiap pengolahannya.

Deskripsi Alternatif :

The Accounting Building is a place of activity for the academic community of the Bandung State Polytechnic. The Accounting Building certainly cannot be separated from lighting to help activities so as to create a comfortable atmosphere. Over time, the Accounting Building underwent many changes such as additions and changes to the function of the room but not accompanied by changes in lights. Therefore, an analysis of the intensity of lighting must be carried out on the 1st Floor of the Accounting Building. The purpose of this final project is to find out the intensity of lighting that occurs on the 1st Floor of the Accounting Building and compare it with the applicable standard rules. The stages of the process carried out in this analysis calculate, measure the intensity of lighting and perform simulations using the Dialux 4 software. The results of lighting intensity on the 1st floor are based on SNI recommendation 6197:2011. Measurements that meet the standards include Class D, Warehouse, and Corridor type B. From calculations that meet the standards, namely Warehouse. From Dialux Simulation 4 daylight that meets the standards including Class type D, Class type E, Warehouse and Corridor type B. The results of Dialux simulation 4 nights that meet the standards include warehouse and corridor type E. The results are obtained differently because there are factors that affect each processing.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Trisno Yuwono Putro, S.T., M.Eng.


    Pembimbing 2: Sunarto, S.T., M.Eng., Editor: Muhammad Abdillah Islamy, S.Pd

Download...