Path: Top > Laporan Penelitian > JURUSAN TEKNIK REFRIGERASI DAN TATA UDARA

Laporan Penelitian Pemula 2021: Tinjauan Pembacaan Variasi Feed Water menggunakan Protocol M-BUS

Research Report from JBPTPPOLBAN / 2024-02-16 14:05:49
Oleh : Muhammad Arman - 196903301999031001 (akangarman@polban.ac.id)
Dibuat : 2022-02-11, dengan 1 file

Keyword : Laporan Penelitian, M-Bus, Variasi Aliran

Di era perkembangan teknologi yang pesat, penggunaan meteran air konvensional masih mendominasi pengukuran konsumsi air. Ini karena harga yang lebih rendah dan pemasangan yang mudah, tetapi untuk menemukan dari total konsumsi air, kami harus memeriksa meter air satu per satu dan mencatat datanya secara manual dari masing-masing meter ini. Tidak hanya menyita cukup banyak waktu dan tenaga, tapi ada juga masih berisiko terjadi kesalahan saat merekam data. Oleh karena itu, untuk menghemat waktu dan tenaga, serta meminimalkan kesalahan dalam pencatatan data, sistem M-Bus digunakan sebagai alat pengukur berbagai sensor aplikasi yang dapat disesuaikan dengan kebutuhan pengguna. Sistem M-Bus menggunakan bus konfigurasi dengan sepasang kabel untuk mengirimkan data terukur dari slave ke master, yaitu terhubung ke komputer sebagai sarana untuk memproses dan menyimpan data yang diperoleh melalui M-Bus Perangkat Lunak Guru v1.3. Dalam penelitian ini, sistem dengan tiga jalur pipa dan hanya dua jalur dengan saluran air meter dan budak yang dipasang berhasil dirancang. Katup manual di setiap pipa digunakan untuk memberikan variasi dalam jumlah konsumsi air. Selain itu, pemanas air otomatis sistem juga dirancang sebagai sistem kontrol. Master M-Bus dan slave M-Bus dikonfigurasi sehingga kedua perangkat dapat saling berkomunikasi secara serial. Pengujian dilakukan untuk melihat fungsionalitas, kinerja, dan akurasinya dalam mengukur konsumsi air.

Deskripsi Alternatif :

In an era of rapid technological development, the use of conventional water meter still dominates the measurement of water consumption. This is due to lower prices and easy installation, but to find out the total water consumption, we have to check the water meters individually and record the data manually from each of these meters. Not only it is taking up quite a lot of time and energy, but there is also still a risk of errors when recording the data. Therefore, to save time and energy, and minimize errors in recording data, the M-Bus system is used as a measurement device for various sensor applications that can be adjusted according to the user’s needs. The M-Bus system uses a bus configuration with a pair of cable to transmit measured data from the slave to the master, which is connected to a computer as a means of processing and storing obtained data through the M-Bus Master v1.3 Software. In this research, system with three pipelines and only two lanes with a water meter and a slave installed is successfully designed. The manual valve in each pipeline is used to provide variation in the amount of water consumption. In addition, an automatic water heating system is also designed as the control system. The M-Bus master and the M-Bus slave is configured so that the two devices can communicate each other serially. The testing has been carried out to see its functionality, performance and accuracy in measuring the water consumption.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • , Editor: Erlin Arvelina

Download...