Analisis Manajemen Perawatan menggunakan Perhitungan Distribusi Weibull pada Air Cooled Chiller FMC-20 di Grand Yogya Kepatihan

Maintenance Management Analysis using Weibull Distribution Calculations on Air Cooled Chiller Fmc-20 in Grand Yogya Kepatihan

Tugas Akhir, 016 / 2020 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2021-12-06 10:27:53
Oleh : Muhammad Fahmi Suherman - 171611018 (muhammad.fahmi.tptu17@polban.ac.id)
Dibuat : 2021-12-06, dengan 4 file

Keyword : weibull distribution, management of maintenance, reliability, failiurebility, availability
Subjek : Distribusi weibull, Manajemen Perawatan, Keandalan, Kerusakan, Ketersediaan

Salah satu aspek penting pada mesin water chiller mall/supermarket agar dapat memberikan kenyamanan termal yang cukup adalah harus diperhatikannya manajemen perawatan pada water chiller itu sendiri. Dengan manajemen perawatan yang baik dapat mempertahankan kualitas water chiller agar tetap bisa bekerja pada waktu yang lama. Sekait dengan hal tersebut, penulis merumuskan judul Analisis Manajemen Perawatan Menggunakan Perhitungan Distribusi weibull Pada Air Cooled Chiller FMC-20 Di Grand Yogya Kepatihan. Rencana tugas akhir penulis adalah menghitung dan menganalisis manajemen perawatan yang meliputi keandalan (reliability), kerusakan (failurability), ketersediaan (availability dan nilai parameter bentuk (β) menggunakan distribusi weibull yang difokuskan pada mesin water chiller model FMC-20. Hasil akhir dari tugas akhir ini dapat diketahui bahwa manajemen perawatan terhadap water chiller, khususnya untuk kondenser berdasarkan perhitungan distribusi weibull belum baik. Berdasarkan hasil perhitungan ditemukan keandalannya rata-rata lebih kecil dari kerusakannya dan ketersediaannya masih belum mencukupi. Selain itu, nilai parameter bentuknya (β) > 1 yang artinya kondenser harus segera diganti karena kerusakan yang cenderung naik.

Deskripsi Alternatif :

One important aspect of a mall / supermarket water chiller machine in order to provide sufficient thermal comfort is that the maintenance management of the water chiller itself must be considered. With good maintenance management, it can maintain the quality of the water chiller so that it can work for a long time. Regarding this, the writer formulated the title "Analysis of Maintenance Management Using Weibull Distribution Calculations on Air Cooled Chiller FMC-20 in Grand Yogya Kepatihan". The author's final project plan is to calculate and manage maintenance that includes (reliability), damage (failure), measurement (availability) and parameter value (β) using the Weibull distribution which is focused on the FMC-20 water cooling machine. The final result of this final project is It can be seen that the maintenance management of water chiller, especially for condensers based on the calculation of the Weibull distribution, is still not good. From the calculation results, it is found that the average is smaller than the damage, as well as measuring it is still not satisfactory. (β)> 1 which means that the condenser must be immediately replaced. replace because the damage tends to rise.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing : Ade Suryatman Margana, S.T., M.Eng., Editor: Muhammad Abdillah Islamy, S.Pd

Download...