Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Refrigerasi & Tata Udara > Program Studi Teknik Pendingin & Tata Udara > 2021

Kaji Eksperimental Pengaruh Pemanfaatan Air Kondensat Untuk Terhadap Performansi AC SplitPendinginan Kompresor

Experimental Study Of The Effect Of Using Condensate Water For Compressor Cooling On Split AC Performance

Tugas Akhir, 018 / 2021 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2024-02-22 09:49:10
Oleh : Muhammad Fikri - 181611019 (muhammad.fikri.tptu18@polban.ac.id )
Dibuat : 2024-02-22, dengan 4 file

Keyword : Compressor, split AC, Condensate Water
Subjek : Kompresor, AC split, Air Kondensat

Sistem refrigerasi kompresi uap memiliki empat komponen utama, yaitu kompresor, kondensor, alat ekspansi dan evaporator. Dalam sistem refrigerasi kompresi uap kompresor mempunyai peranan yang sangat penting yaitu jantung dalam sistem refrigerasi. Kompresor merupakan komponen yang berfungsi mensirkulasikan refrigeran ke semua komponen refrigerasi. Pada sistem AC Split kompresor disatukan tempatnya dengan kondensor yang disebut condensing unit. Condensing unit terletak dibagian luar ruangan yang biasa disebut outdoor unit. Ketika sistem AC Split bekerja selalu menghasilkan air kondensat yang berasal dari kondensasi uap air di evaporator. Pada umumnya air kondensat ini terbuang sia-sia ke lingkungan dan tidak termanfaatkan. Air kondensat mempunyai temperatur sekitar 5⁰C - 10⁰C,sehingga bisa digunakan untuk pendinginan. Data hasil pengukuran digunakan untuk dapat digambarkan pada diagram Psikrometrik, maka dapat dicari diantaranya parameter utama dalam penulisan laporan ini yaitu Kapasitas pendinginan, coefficient of performance (COP) dan Energy Efficiency Ratio (EER). Besar pengaruh pemanfaatan air kondensat untuk pendinginan kompresor pada daya input mengalami penurunan sebesar 0,05 kW, pada kapasitas pendinginan mengalami kenaikan sebesar 0,25 kW, coefficient of performance (COP) mengalami kenaikan sebesar 0,70 dan Energy Efficiency Ratio (EER) mengalami kenaikan sebesar 2,39 Btuh/W dibandingkan saat sistem dijalankan tanpa pemanfaatan air kondensat.

Deskripsi Alternatif :

English: The vapor compression refrigeration system has four main components, namely the compressor, condenser, expansion device and evaporator. In the vapor compression refrigeration system, the compressor has a very important role, namely the heart in the refrigeration system. The compressor is a component that functions to circulate refrigerant to all refrigeration components. In Split AC systems the compressor is not paired with the condenser which is called the condensing unit. The condensing unit is located outside the room which is usually called the outdoor unit. When the Split AC system works, it always produces air condensate from the condensation of water vapor in the evaporator. In general, this air condensate is wasted into the environment and is not utilized. Air condensate has a temperature of about 5⁰C - 10⁰C, so it can be used for cooling. The results of the measurement data used can be described on a psychometric diagram, so it can be searched for, among others, the parameters in writing this report, namely cooling capacity, coefficient of performance (COP) dan Energy Efficiency Ratio (EER). The influence of the use of condensate water for compressor cooling on input power has decreased by 0.05 kW, the cooling capacity has increased by 0.25 kW, the coefficient of performance (COP) has increased by 0.70 and Energy Efficiency Ratio (EER) increased by 2.39 Btuh/W compared to when the system was run without the use of condensate water.

Beri Komentar ?#(1) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Prof. Dr. Ir. Andriyanto Setyawan, M.T.


    Pembimbing 2: Tandi Sutandi, S.ST., M.T., Editor: Muhammad Abdillah Islamy, S.Pd

Download...