Jaringan sistem pendistribusian tenaga listrik di ULP Malingping memiliki total jaringan tegangan menegah dengan panjang 47,55 kms dengan saluran udara kabel berinti alumunium. Dikarenakan panjangnya penyulang tersebut, jaringan distribusi tenaga listrik ini menjadi rentan terkena gangguan. Untuk menjamin kontinuitasnya, maka diperlukan peralatan proteksi yang akan berkoordinasi untuk mendeteksi dan memperbaiki gangguan agar sistem kelistrikan bisa berjalan dengan baik kembali sesuai dengan syarat sistem proteksi. Karya tulis ini bertujuan untuk mengetahui cara kerja diantara Recloser dan Sectionalizer serta menghitung nilai SAIFI, SAIDI dan CAIDI pada salah satu penyulang di ULP Malingping yaitu Penyulang Bayahkota. Kemudian hasil perhitungan tersebut akan disesuaikan dengan standar yang berlaku yaitu SPLN 68 - 2 tahun 1986. Tujuan tersebut dicapai dengan metode deduktif atau proses mengurangi dari satu atau lebih informasi umum untuk sampai pada kesimpulan yang benar. Metode deduktif juga akan meneguhkan suatu realitas baru yang berasal dari realitas yang sudah ada dan sudah diketahui. Hasil dari penelitian yang dilakukan adalah berupa nilai SAIFI dari Penyulang Bayahkota yaitu sebesar 0, 385625827 kali/pelanggan/tahun, sementara nilai SAIDI sebesar 0,008058322 jam/tahun dan nilai CAIDI sebesar 0,020896738 jam / tahun. Penyulang Bayahkota dapat dikatakan andal dalam penyaluran energi listrik karena berdasarkan SPLN 68 - 2 tahun 1986 batas nilai SAIFI adalah sebesar 2,4 kali/tahun dan nilai SAIDI yaitu sebesar 12,8 jam/tahun.
Deskripsi Alternatif :The network of electric power distribution system in ULP Malingping has a total voltage network with a length of 47.55 kms with aluminum cable air lines. Because of the length of the refiner, this electric power distribution network becomes vulnerable to interference. To ensure continuity, protection equipment is needed that will coordinate to detect and fix interference so that the electrical system can run properly again in accordance with the requirements of the protection system. This paper aims to find out how it works between Recloser and Sectionalizer and calculate the value of SAIFI, SAIDI and CAIDI to one of the refiners at ULP Malingping, namely Bayahkota Refiner. Then the results of the calculation will be adjusted to the applicable standard that is SPLN 68 - 2 in 1986. Such goals are achieved by deductive methods or the reasoning process of one or more general statements to reach one logical conclusion. Deductive methods will also prove a new truth derived from the truth â the truth that already exists and is known before. The results of the research conducted were in the form of SAIFI value from Bayahkota Refiners which is 0.385625827 times / customer / year, while SAIDI value of 0.008058322 hours / year and CAIDI value of 0.020896738 hours / year. Bayahkota refiners can be said to be reliable in the distribution of electrical energy because based on SPLN 68 - 2 of 1986 the saifi value limit is 2.4 times / year and the SAIDI value is 12.8 hours / year.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Yudi Prana Hikmat, S.T., M.T.
Pembimbing 2: Toto Tohir, S.T., M.T., Editor: Muhammad Abdillah Islamy, S.Pd
Download...
File : KELENGKAPAN TA - 181321055.pdf
(1707610 bytes)
File : BAB 1 - 181321055.pdf
(144990 bytes)
File : BAB 2 - 181321055.pdf
(383967 bytes)
File : BAB 5 - 181321055.pdf
(135809 bytes)