Analisis Pengaruh Variasi Temperatur Bola Kering dengan Rasio Kelembaban Konstan Pada Kondensor terhadap Kinerja AC Split
Analysis of The Effect of Dry Bulb Temperature Variations with a Constant Humidity Ratio on The Condenser to The Performance of Split Air Conditioning
Tugas Akhir, 048 / 2020 / RTUUndergraduate Theses from JBPTPPOLBAN / 2021-12-17 10:04:19
Oleh : Putri Endah Pratiwi - 171611054 (putri.endah.tptu17@polban.ac.id )
Dibuat : 2021-12-17, dengan 4 file
Keyword : AC Split, Tdb, humidity ratio, Split AC performance
Subjek : AC Split, Tdb, Rasio kelembaban, kinerja AC Split
Pendingin udara jenis AC Split terdiri dari dua bagian utama yaitu bagian dalam (indoor unit) yang dipasangkan di dalam ruangan dan bagian luar (outdoor unit) yang dipasang dibagian luar ruangan. Dua parameter penting dari AC adalah temperatur kelembaban. Kedua parameter tersebut akan mempengaruhi kinerja dari salah satu bagian AC yaitu kondensor. Dalam hal ini, kelembaban udara yang merupakan banyaknya kadar uap air yang terdapat pada campuran udara atmosfer ikut mempengaruhi besarnya laju perpindahan panas pada kondensor. Tujuan pengujian adalah untuk mengetahui pengaruh variasi temperatur bola kering (Tdb) dengan rasio kelembaban konstan pada kondensor terhadap kinerja AC Split. Berdasarkan hasil pengujian yang telah dilakukan dengan variasi Temperatur bola kering 24 ºC, 26 ºC, 28 ºC, 30 ºC, 32 ºC, 34 ºC, 36 ºC dan 38 ºC dengan rasio kelembaban 0,01331 kga/kgda pada AC Split 9000 Btu/h menggunakan refrigerant R32 berpengaruh terhadap kinerja AC Split, ditunjukan dengan penurunan kapasitas pendingin sebesar 10,86%, daya input mengalami kenaikan sebesar 20%, EER turun sebesar 26% dan COPactual turun sebesar 16%.
Deskripsi Alternatif :plit system air conditioning consist of two main part, namely inside (Indoor unit) which is installed indoor and outside (Outdoor unit) which is installed outside the room. Two important parameters of Air Condtioning are the humidity and temperature. These two parameters will affect the performance of one part of the air conditioing which is the condenser. In this case, humidity is the number of levels of water vapor contained in the mixture of atmospheric air effected the magnitude of the rate heat transfer in the condenser. The purpose of testing is to determine the influence of variations in dry ball temperature (Tdb) with a constant humidity ratio on the condenser to the performance of AC Split. Based on the results of the tests which have been done with variations of the temperature dry bulb 24 ºC, 26 ºC, 28 ºC, 30 ºC, 32 ºC, 34 ºC, 36 ºC and 38 ºC with a humidity ratio of 0.01331 kga/kgda on AC Split 9000 Btu/h using refrigerant R32 affects the AC Split Performance, indicate by a decrease in cooling capacity of 10.86%, input power has increased by 20%, EER decreased by 26% and COPactual decreased by 16%.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Dr. Ir. Andriyanto Setyawan, M.T.
Pembimbing 2: Susilawati, S.T., M.Eng.
Pembimbing 3: Hafid Najmudin, S.T., Editor: Muhammad Abdillah Islamy, S.Pd
Download...
File : KELENGKAPAN TA - 171611054.pdf
(828944 bytes)
File : BAB 1 - 171611054.pdf
(231272 bytes)
File : BAB 2 - 171611054.pdf
(300236 bytes)
File : BAB 5 - 171611054.pdf
(223533 bytes)