Kaji Eksperimental Perbandingan Kinerja Mesin Ice Cube Maker Menggunakan Pipa Kapiler dan TXV

The Experimental Study of Ice Cube Maker Performance Using Capillary Tube and TXV

Tugas Akhir, 021 / 2020 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2021-12-07 09:45:26
Oleh : Raka Noerman Khatami - 171611023 (raka.noerman.tptu17@polban.ac.id)
Dibuat : 2021-12-07, dengan 4 file

Keyword : Refrigeration System, Ice Cube Maker, Capillary Tubes, TXV, Performance
Subjek : Sistem Refrigerasi, Ice Cube Maker, Pipa Kapiler, TXV, Performansi

Ice Cube Maker merupakan mesin pembuat es batu secara otomatis. Sistem yang digunakan adalah sistem refrigerasi kompresi uap berkapasitas ¼ PK. Salah satu komponen utama sistem refrigerasi kompresi uap adalah alat ekspansi. Penggunaan dua jenis alat ekspansi dapat dilakukan untuk mengetahui jenis alat ekspansi yang menghasilkan kinerja paling baik. Pada tugas akhir ini dilakukan kaji eksperimental untuk mengetahui perbandingan kinerja dari Ice Cube Maker menggunakan alat ekspansi TXV dan pipa kapiler. Pengujian dilakukan dengan cara menjalankan sistem tersebut lalu dilakukan pengamatan untuk masing masing alat ekspansi. Hasil pengujian menunjukkan efisiensi sistem dengan menggunakan alat ekspansi TXV adalah 82,1% sedangkan sistem yang menggunakan pipa kapiler adalah 79,7%. Sementara pemakaian energi listrik sistem dengan menggunakan alat ekspansi TXV 0,140 kWh lebih rendah dibandingkan dengan alat ekspansi pipa kapiler hal ini dipengaruhi chilling time dari alat ekspansi pipa kapiler yang lebih lama. Berdasarkan hasil pengujian, penggunaan alat ekspansi TXV lebih unggul daripada pipa kapiler sehingga Ice Cube Maker ini lebih cocok menggunakan alat ekspansi TXV.

Deskripsi Alternatif :

Ice Cube Maker is an automatic ice cube maker. The system used is a vapor compression refrigeration system with a capacity of ¼ PK. One of the main components of the vapor compression refrigeration system is an expansion device. The use of two types of expansion devices can be used to determine which type of expansion device produces the best performance. In this final project, an experimental study was conducted to determine the performance comparison of the Ice Cube Maker using the TXV expansion device and capillary tube. Testing is done by running the system and then making observations for each expansion device. The test results show the efficiency of the system using the TXV expansion device is 82.1% while the system using capillary pipe is 79.7%. While the electrical energy consumption of the system using the TXV expansion tool 0.140 kWh is lower than the capillary pipe expansion device, this is influenced by the chilling time of the longer capillary pipe expansion device. Based on the test results, the use of the TXV expansion tool is superior to the capillary pipe so that the Ice Cube Maker is more suitable for using the TXV expansion tool.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Tandi Sutandi, S.ST., M.T.


    Pembimbing 2: Apip Badarudin, S.T., M.T., Editor: Muhammad Abdillah Islamy, S.Pd

Download...