Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Elektro > Program Studi Teknik Listrik > 2021
Studi Koordinasi Proteksi Penyulang SUTM Pada Gardu Induk Padalarang Menggunakan Software ETAP 16.0.0
Study of SUTM Feeder Protection Coordination at Padalarang Substation using ETAP 16.0.0 Software
Tugas Akhir, 058 / 2021 / TLIUndergraduate Theses from JBPTPPOLBAN / 2023-03-13 11:11:26
Oleh : Ranti Aulia Putri Ramdani - 181321059 (ranti.aulia.tlis18@polban.ac.id )
Dibuat : 2023-03-13, dengan 4 file
Keyword : Coordination of protection ; over current relays; fuse cut out; recloser
Subjek : Koordinasi proteksi ; over current relay; fuse cut out; recloser
Gangguan yang terjadi pada saluran tegangan menengah yaitu gangguan sementara dan permanen. Koordinasi fuse cut out dan recloser dibutuhkan untuk mengurangi jumlah gangguan dan menghemat fuse. Untuk mempelajari mekanisme koordinasi tersebut dilakukan penelitian di penyulang Rajamandala di gardu induk Padalarang. Tujuan dari penelitian ini adalah mengetahui mekanisme koordinasi proteksi over current relay, fuse dan recloser, melalui evaluasi berdasarkan simulasi ETAP. Metode yang dilakukan pada penelitian ini adalah perhitungan arus hubung singkat untuk mengetahui arus hubung singkat tiga fasa, dua fasa dan satu fasa ke tanah pada jarak 0% dan 100%, menghitung nilai setting over current relay, setting recloser, rating fuse, simulasi load flow analysis untuk melihat aliran arus, aliran daya aktif dan daya reaktif yang mengalir pada setiap gardu distribusi, simulasi short circuit analysis untuk mengetahui besarnya arus hubung singkat yang dihasilkan pada saat simulasi gangguan hubung singkat, dan simulasi star protective device untuk melihat koordinasi proteksi antara over current relay, fuse cut out, dan recloser. Hasil dari penelitian ini yaitu dari ketiga fuse yang disimulasi gangguan hubung singkat satu fasa, koordinasi proteksinya telah sesuai dengan skema fuse saving yang diinginkan yaitu untuk fuse 1 akan beroperasi dengan waktu pemutusan 69,9 ms, Untuk fuse 3 akan beroperasi dengan waktu pemutusan 64,6 ms, kemudian untuk fuse 4 akan beroperasi dengan waktu pemutusan 117 ms.
Deskripsi Alternatif :Disturbances that occur in the medium voltage line are temporary and permanent disturbances. Coordination of fuse cut out and recloser is need to reduce number of distractions and saving the fuse. To study the coordination mechanism, research was conducted at the Rajamandala feeder at the Padalarang substation. The purpose of this research is to know the coordination mechanism of over current relay, fuse and recloser protection, through evaluation based on ETAP simulation. The method used in this study is the calculation of short-circuit current to determine the short-circuit current of three-phase, two-phase and one-phase to ground at a distance of 0% and 100%, calculating the value of setting over current relay, setting recloser, rating fuse, load flow analysis simulation to see the current flow, active power flow and reactive power flowing at each distribution substation, short circuit analysis simulation to determine the amount of short circuit current generated during short circuit fault simulation, and star protective device simulation to see the protection coordination between over current relay, fuse cut out, and recloser. The results of this study are from the three fuses that simulated a single-phase short circuit, the protection coordination is in accordance with the desired fuse saving scheme which for fuse 1 it will operate with a disconnection time of 69.9 ms, for fuse 3 it will operate with a disconnection time of 64.6 ms, then for fuse 4 will operate with a disconnection time of 117 ms.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Supriyanto, S.T., M.T.
Pembimbing 2: Yudi Prana Hikmat, S.T., M.T., Editor: Muhammad Abdillah Islamy, S.Pd
Download...
File : KELENGKAPAN TA - 181321059.pdf
(1663934 bytes)
File : BAB 1 - 181321059.pdf
(803609 bytes)
File : BAB 2 - 181321059.pdf
(1484165 bytes)
File : BAB 5 - 181321059.pdf
(714275 bytes)