Keyword : beam, column, joint, concrete jacketing, CFRP, foundation strengthening
Subjek : balok, kolom, joint, concrete jacketing, CFRP, perkuatan fondasi

Gedung Kantor Terminal Bahan Bakar Minyak (TBBM) Pertamina yang berlokasi di Jalan Jampea, Tanjung Priok, Jakarta Utara, akan ditingkatkan kapasitasnya dari tiga lantai menjadi lima lantai. Hal ini didasari oleh meningkatnya aktivitas administrasi yang dilakukan di gedung tersebut. Dengan adanya penambahan dua lantai baru pada gedung tersebut perlu dievaluasi terhadap stabilitas, kekakuan, dan kekuatan strukturnya. Sebelum melakukan evaluasi pada elemen balok dan kolom eksisting, terlebih dahulu dilakukan investigasi struktur atas dan investigasi struktur bawah. Berdasarkan hasil pengujian hammer test diketahui mutu kolom eksisting sebesar 26,58 MPa dan mutu balok eksisting sebesar 21,18 MPa, sedangkan berdasarkan hasil pengujian core drill test diketahui mutu pelat eksisting sebesar 23,72 MPa. Hasil uji SPT dan pengujian laboratorium tanah diketahui sampai kedalaman 26 m merupakan tanah lunak yang didominasi oleh lapisan lempung setebal 18 m. Tahapan analisis desain penampang struktur pada lantai baru meliputi analsis pembebanan struktur, pemodelan struktur, analisis perancangan elemen balok, kolom, dan pelat lantai. Perancangan elemen balok, kolom dan pelat menggunakan metode trial and error yang mengikuti aturan SNI 03-2847-2019. Sementara tahapan analisis pada struktur eksisting meliputi pengolahan data hasil investigasi yang diperoleh, analisis struktur, perencanaan perkuatan, pembuatan metode pekerjaan, dan spesifikasi teknis. Perlemahan struktur eksisting terhadap gaya dalam pada elemen balok induk dan kolom utama diperkuat dengan metode concrete jacketing. Perlemahan struktur eksisting terhadap gaya dalam pada elemen balok anak dan kolom yang bukan merupakan stuktur utama diperkuat dengan CFRP. Sedangkan perlemahan terhadap gaya dalam pada fondasi diperkuat dengan menambahkan fondasi tiang baja H300.300.10.15.

Deskripsi Alternatif :

The Pertamina Oil Fuel Terminal Office Building, which is located at Jalan Jampea, Tanjung Priok, North Jakarta, will increase its capacity from three floors to five floors. This is based on the increase in administrative activities carried out in the building. With the addition of two new floors to the building, the building needs to be evaluate for the stability, stiffness and strength of the structure. Before evaluating the existing beam and column elements, first an investigation of the upper structure and substructure investigation. Based on the hammer test results, it is known that the quality of the existing column is 26.58 MPa and the quality of the existing beam is 21.18 MPa, while based on the results of the core drill test it is known that the quality of the existing plate is 23.72 MPa. The results of the SPT test and soil laboratory testing are known to be soft soil that is dominated by a layer of clay with a thickness of 18 m. The stages of structural cross-sectional design analysis on new floors include structural loading analysis, structural modeling, design analysis of beam elements, columns and floor slabs. The design of beam, column and plate elements uses a trial and error method that follows the SNI 032847-2019 rules. Meanwhile, the analysis stage of the existing structure includes processing the data from the obtained investigation results, structural analysis, retrofitting, making work methods, and technical specifications. The attenuation of the existing structure against internal forces on the main beam and main column elements is reinforced by the concrete jacketing method. The attenuation of the existing structure against internal forces on joist elements and columns which are not the main structure is reinforced by CFRP. Meanwhile, the attenuation of internal forces on the foundation is strengthened by adding a steel pile foundation H300.300.10.15.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Dr. Ir. Riawan Gunadi, M.T.

    Pembimbing 2: Andri Krisnandi, S.ST., M.Eng., Editor: Muhammad Abdillah Islamy, S.Pd

Download...